![Thermadyne Thermal Arc 185TSW Operating Manual Download Page 23](http://html1.mh-extra.com/html/thermadyne/thermal-arc-185tsw/thermal-arc-185tsw_operating-manual_1103102023.webp)
23
Gnd.
1 2 3 4 5 6 7 8
2
1
5
4
3
8
7
6
5k Ohms
Front view of 8-Socket Receptacle
4.0 OPERATOR CONTROLS
4.01 Pro-Wave 185TSW Controls
Figure 4– Pro-Wave 185TSW Power Source
1
Control Knob
This control sets the selected weld parameter, rotating it clockwise increases the parameter
that is indicated on the digital meter. Pushing the knob inward displays the actual welding
voltage.
2
Remote Control Socket
The 8 pin Remote Control Socket is used to connect remote current control devices to the
welding Power Source. To make connections, align keyway, insert plug, and rotate threaded
collar fully clockwise.