Thermador TCM24TS Installation Instructions Manual Download Page 8

4

en

Included in delivery

Fully automatic coffee machine

Installation instructions 

Assembly bracket

Transformer mount 

Spacers

7 fastening screws (silver)

2 fastening screws (long/black)

1 sleeve (black)

2 fastening screws (short/black)

2 sleeves (white)

Transformer

Prepare built-in units

Important:

 The power outlet must be located outside the 

built-in cut-out.

Make sure there is adequate aeration. To do this, remove 

the rear panel or cut out an opening of 19

11

16

″ x 15

3

4

″ 

(500 x 400 mm)

. There must be a gap of at least 1

3

8

 (35 mm) 

between the wall and base of the unit or the rear panel of the 

unit situated above. The ventilation slots and intake openings 

must not be covered. Also follow the installation instructions for 

the appliance situated above or below. If installing the appliance 

above a warming drawer, the height of the recess must be 23

1

4

 

(590 mm). If the appliance is installed directly under a décor 

panel, ensure that there is a ventilation slot of at least 31 square 

inches (200 cm

2

). The ideal installation height for the fully 

automatic coffee machine, measured from the floor to the lower 

edge of the appliance, is 37

7

16

″ (950 mm)

.

Protect your Coffeemaker against freezing or it will be 

damaged.

 

¡

 CAUTION

Installation must always be performed by 2 persons.

Installation preparation 

Unpack all the parts and check for any damage in transit. 

Do not operate a damaged appliance.

Take note of the installation dimensions of the particular 

model.

Important:

 Two openings angles can be selected for the 

door. Depending on the opening angle required, the mounting 

distance to the wall should be observed before installation.

 

● Opening angle approx. 110° (delivery status)

 

= mounting distance to the wall at least 13

3

4

 (350 mm).

 

● Opening angle approx. 155°

 

= mounting distance to the wall at least 25

9

16

 (650 mm).

For an opening angle of 155°, remove both the restrictors at the 

top and bottom of the hinge.

Remove the installation template on the back of the 

installation instructions. Place the installation template at the 

front edge of the unit and screw on the assembly bracket 

c

 

as shown with two fastening screws 

f

. The assembly 

bracket must be positioned at the base of the unit and the 

wall such that no gap is present.

Fasten the the transformer mount 

d

 with two screws 

f

 in 

the middle.

Insert the transformer in the mount. The connections to both 

lines must point to the left.

Note:

 When positioning the transformer 

k

 and pushing in the 

appliance, do not trap the lines. 

The transformer 

k

 is not allowed to touch the appliance and 

the back wall of the cupboard.

Set the mains switch 

U

 to 

h

 on the appliance.

Securely insert the front line into the appliance (snaps into 

place). For this purpose, put the appliance to be plugged 

in just on to the edge of the unit. Plug the power cord into 

the socket. Plug transformer into dedicated receptacle in an 

accessible cabinet adjacent to the coffee maker (depends 

on the built-in situation). Do not plug into a receptacle 

behind the appliance.

Push the appliance into the unit until it clicks into place. 

Check that the appliance is in the middle. If necessary, 

align the appliance. To do so, pull the appliance out a little, 

remove the appropriate spacers 

e

 and attach to the left 

side (top and bottom). Push the appliance into the unit until 

it clicks into place.

Take hold of the appliance door on the right next to the 

outlet and open. Remove the drip tray 

Y

. Pull the cover 

X

 on 

the bottom left-hand side forwards and remove. Pull out the 

accessories drawer 

Z

 and put to one side.

10 

First, screw on the appliance as shown using 2 of each 

of the fastening screws 

f

 and 

g

 as well as 2 sleeves 

j

Then screw tight at the top right of the unit using 1 fastening 

screw 

f

 and sleeve 

h

.

11  Only for the expert

 

In very few cases, the door of the fitted fully automatic 

machine can jam due to a warpage in the built-in units. The 

door can be adjusted. To do this adjust the hinges at the top 

and the bottom.

I. 

Adjust the depth of the door by turning the screws 

V

.

II. 

Remove the hinge dampers at the top and bottom of the 

hinges. Turn the screws 

W

 to adjust the inclination and 

the horizontal position of the doors. 

III. 

Re-fit the hinge dampers.

12 

Insert the cover 

X

 and fix with the two black fastening 

screws 

i

.

13 

Replace the drip tray 

Y

 and accessories drawer 

Z

 and close 

the appliance door.

Removal

 

Undo all screws.

 

Slightly pull out the appliance.

 

Remove the power cord from the socket.

 

Disconnect the appliance from the transformer.

 

Fully remove the appliance.

Technical specifications

Power connection  

with transformer type 8001010566  

(voltage – frequency)

120 V AC – 60 Hz

Power rating

1600 W

Maximum static pump pressure

19 bar

Maximum water tank capacity 

(without filter) 

81.15 oz (2.4 l)

Maximum capacity of the 

 

coffee bean container

1 lb (500 g)

Length of power cable  

(Power socket – transformer)

39

″ (

1 m)

Dimensions  

(appliance without transformer)  

H x B x D

17 7⁄8″ x 23 3⁄8″ x 14 3⁄4″

 

(455 x 596 x 375 mm)

Weight, empty  

(appliance without transformer)

42-44 lb (19-20 kg)

Dimensions (only transformer)  

H x B x D

8 1⁄4″ x 6 3⁄4″ x 6 3⁄4″

  

(210 x 172 x 198 mm)

Weight (only transformer)

27.55 lb (12.5 kg)

Type of grinding unit

Ceramic 

Summary of Contents for TCM24TS

Page 1: ...USEAND CARE GUIDE USEAND CARE GUIDE BUILT IN COFFEE MACHINE TCM24TS ...

Page 2: ...1 32 in 1 16 in 1 8 in 1 6 in 233 8 596 mm 110 110 177 8 455 mm 1711 16 449 mm 22 558 mm 143 4 356 mm 92 00636455 92 155 110 155 k e d c b a f i g h j U 1 en English 3 fr Français 5 es Español 7 ...

Page 3: ...min 133 4 350 mm 110 min 315 16 100 mm 92 min 259 16 650 mm 155 f h 173 4 1 16 450 2 mm 231 4 1 4 590 6 mm 377 16 950 mm min 13 8 35 mm 231 2 597 mm 221 16 5 16 560 8 mm 13 16 30 mm c f k d f 2 3 5 6 4 ...

Page 4: ... 1 32 in 1 16 in 1 8 in 1 6 in 221 8 226 16 562 568 mm 221 16 560 mm Y Z X e e e II 120VAC I III II III I 221 8 562 mm 223 16 564 mm 225 16 566 mm 226 16 568 mm 8 7 9 ...

Page 5: ...X i V W III f g j j h f f g I II 11 12 10 ...

Page 6: ...Z Y 13 ...

Page 7: ... or any liquid Grounding This appliance may only be connected to a power supply with 120 Volt AC via a correctly installed receptacle with ground WARNING Repairs To avoid potential hazards repairs must only be carried out by authorized service personnel If the power cord of this appliance is damaged it must be replaced by a original replacement power cord which can be purchased from our Customer S...

Page 8: ...p the lines The transformer k is not allowed to touch the appliance and the back wall of the cupboard 6 Set the mains switch U to h on the appliance 7 Securely insert the front line into the appliance snaps into place For this purpose put the appliance to be plugged in just on to the edge of the unit Plug the power cord into the socket Plug transformer into dedicated receptacle in an accessible ca...

Page 9: ... L appareil doit être branché à une source de courant alternatif de 120 volts via une prise correctement mise à la terre AVERTISSEMENT Réparations Afin d éviter tous les risques seul un personnel de service autorisé peut réparer cet appareil Si le cordon d alimentation secteur de cet appareil est endommagé il doit être remplacé par un câble de rechange d origine disponible auprès de notre service ...

Page 10: ...e pas bloquer les lignes au moment de positionner le transformateur k et de le pousser dans la machine Le transformateur k ne doit pas toucher la machine et le panneau arrière de lʼarmoire 6 Commuter lʼinterrupteur principal U sur h 7 Positionner la ligne avant dans lʼappareil sʼencliquette À cet effet poser légèrement lʼappareil sur lʼarmoire pour le brancher Brancher le cordon dʼalimentation dan...

Page 11: ...de suministro de agua La conexión eléctrica deberá realizarse hasta después de efectuar la conexión de agua ADVERTENCIA Conexión a tierra El aparato debe ser conectado únicamente a una alimentación eléctrica con corriente alterna de 120 voltios a través de un tomacorriente instalado correctamente con tierra física Reparaciones Las reparaciones en el aparato deben ser realizadas sólo por personal d...

Page 12: ...itido que el transformador k toque el aparato ni la pared posterior de la alacena 5 Coloque el interruptor principal U hacia h en el aparato 6 Inserte con cuidado el cable frontal en el aparato queda en su lugar al sonar un chasquido Para lograrlo coloque el aparato para que se enchufe justo sobre el borde de la unidad Enchufe el cable de alimentación en el tomacorriente Enchufe el transformador a...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...8001141360 8001141360 15 THD 0402 5 15 1901 Main Street Suite 600 Irvine CA 92614 1 800 735 4328 www thermador com 2015 BSH Home Appliances 990207 f h c f ...