Service Manual for Thermador Pro Grand Dual Fuel Ranges:
PRD304EG,
PRD364EDG, PRD364EDPG, PRD364ELG, PRD366EG, PRD366EPG, PRD484ECG, PRD484EEG, PRD486EDG, PRD486EDPG, PRD486ELG
58300000157422_ARA_EN_A
Page 30 of 95
4.3.2 Griddle with Fixed Brackets – Removal and Replacement
Fiberglass
Wear gloves when handling fiberglass insulation
Griddle Hazard
The griddle plate must always be correctly in place when it is on.
1. Follow all safety precautions and steps in
page
2.
Accessing Components under the Maintop,
page
3. Remove the griddle plate and grease tray (see Figure 38,
4. Carefully remove the bulb from the fixed retaining bracket (see
NOTE:
After removing the thermostat bulb from retaining bracket,
don’t push the bulb through the receptacle in the element tray yet.
5. Disconnect the 1/4 inch spade connectors of both right and left
element wires. You may have to pull the element wires out a bit to
access the connectors – while doing this, be careful not to
damage the element wires.
Figure 48: Removing Thermostat Bulb from Retaining Bracket
1 Retaining
bracket
2 Thermostat
bulb
3
Receptacle for removing bulb