Installation Instructions
English | 7 |
Installation Clearances
Figure 1: Clearance Requirements
5
" (127 mm) min.
to combustible
sidewalls
5" (1
27 m
m) m
in.
to c
om
bus
tible
side
walls
5" (127 mm) min.
to combustible
sidewalls
30" (762 mm) min.
from bottom of overhead
hood to cooking surface.
36" (914 mm) min. if
hood contains
combustible material
30
" (
76
2 m
m)
m
in.
fro
m
bo
tto
m
of
ov
erh
ea
d
ho
od
to
co
ok
ing
su
rfa
ce
.
36
" (
91
4 m
m)
m
in.
if
ho
od
co
nta
ins
co
mb
us
tib
le
ma
ter
ial
30" (762 mm) min.
from bottom of overhead
hood to cooking surface.
36" (914 mm) min. if
hood contains
combustible material
13" max.
cabinet
depth
13
" m
ax
.
ca
bin
et
de
pth
13" max.
cabinet
depth
as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1
scope and are not certified by CSA. Clearances of less than 12" (305 mm)
must be approved by the local codes and/or by the local authority having
jurisdiction.
30", 36", or 48"
(762, 914, or 1219 mm)
30",
36
", o
r 48
"
(76
2, 9
14,
or 1
219
m
m)
30", 36", or 48"
(762, 914, or 1219 mm)
18
" (457 mm)
minimum
18
" (4
57
m
m)
mi
nim
um
18
" (457 mm)
minimum
0" Sides
0" S
ide
s
0" Sides
0" Bottom
0" B
otto
m
0" Bottom
Horizontal minimum distance
to combustible surface:
0" with Backguard
12" (305 mm) with Flush Island
Trim
Hor
izon
tal m
inim
um
dis
tan
ce
to c
om
bus
tible
sur
face
:
0" w
ith B
ack
gua
rd
12"
(30
5 m
m) w
ith F
lush
Isla
nd T
rim
Horizontal minimum distance
to combustible surface:
0" with Backguard
12" (305 mm) with Flush Island
Trim
Shaded area above
countertop indicates min.
clearance to combustible
surfaces, combustible
materials cannot be located
within this area with Flush Island Trim.
Sha
ded
are
a a
bov
e
cou
nte
rtop
ind
icate
s m
in.
clea
ran
ce to
com
bus
tible
surf
ace
s, c
om
bus
tible
ma
teria
ls c
ann
ot b
e lo
cate
d
with
in th
is a
rea
with
Flu
sh Is
land
Trim
.
Shaded area above
countertop indicates min.
clearance to combustible
surfaces, combustible
materials cannot be located
within this area with Flush Island Trim.
See the Ventilation Planning Guide
for recommended hood options.
See the Ventilation Planning Guide
for recommended hood options.
See the Ventilation Planning Guide
for recommended hood options.
m
CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface
CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface
CAUTION!
36" (914 mm) min.
to combustible
material
from Cooking
Surface