Installation Instructions
English | 10 |
Figure 8: Installation of 48'' rangetop above two side-by-side
THERMADOR warming drawers - Model No. WD24
Figure 9: Installation of 48'' rangetop above two side-by-side
THERMADOR warming drawers - Model No. WD24
22
46¼"
(1,175 mm)
22½"
(572 mm)
7
WD24
Cutout
WD24
Cutout
13/16"
(21 mm)
2¾" (70 mm) Vertical Distance
Between Cutouts
(See Side View for Wood Support)
1⅞" (48 mm)
Horizontal Distance
Between Cutouts
Minimum 3/4" (19 mm)
0" to 1¼"
(0 - 32 mm)
See Fig. 4
and Table
Dimension C
9"
(229 mm)
(195 mm)
13
/
16
"
(580 mm)
11
/
16
"
Plywood support
Install additional
wood support along
front edge of cutout
2¾" (70 mm
minimum
between
cutouts
7
11
/
16”
(195 mm)
REAR
Figure 10: Bottom of Unit
¾" (19 mm) flex line
¾" (19 mm) flex line
¾" (19 mm) flex line
½" (12.7 mm) NPT
½" (12.7 mm) NPT
½" (12.7 mm) NPT
A manual valve must be installed external
to the appliance, in an accessible location
A manual valve must be installed external
to the appliance, in an accessible location
A manual valve must be installed external
to the appliance, in an accessible location
from the front, for the purpose of shutting
off the gas supply.
from the front, for the purpose of shutting
off the gas supply.
from the front, for the purpose of shutting
off the gas supply.
From left side to
centerline of gas inlet
5⅝" (143 mm)
From rear to centerline
of gas inlet
8½" (215 mm)
GAS INLET LOCATION