English 5
FLUSH INSTALLATION DIMENSIONS AND CLEARANCES
Figure 4
Figures 2, 3 and 4 contain
many MicroDrawer™ microwave
oven measurements for reference when planning the drawer’s
location.
This MicroDrawer™ microwave oven c
an be installed below
any electric or gas wall oven.
NOTICE:
Always allow sufficient power cord length to the
electrical outlet to prevent tension.
Always check electrical codes for requirements.
MicroDrawer™ Microwave Oven Measurements
23
1
/
2
"
(597 mm)
21
7
/
8
"
(555 mm)
Base min.
depth
27"
(686 mm)
1"
(25 mm)
1"
(25 mm)
36"
(914 mm)
24
3
/
16
"
(614 mm)
22
1
/
8
"
(562 mm)
Frontview cut out
Cleat
14
5
/
8
" (371 mm)
16
5
/
8
"
(422 mm)
cutout
6" (152 mm)
4" (102 mm)
5" (127 mm)
2
1
/
4
" (57 mm)
1
5
/
8
"
(41 mm)
1
/
2
"
(13 mm)
visible
area
1
/
4
"
(6 mm)
base
thickness
* Suggested location of electrical outlet
** Anti-Tip Block
*** Base should support up to 100 lbs
**** Sides should be finished and extend back to cleat.
Cleats should also be finished, as they may be
visible after installation.
(Cleats are not included with unit.)
*
**
***
****
Anti-Tip Block
NORMAL INSTALLATION STEPS
Anti-Tip Block Installation Instructions
The anti-tip block reduces the risk of drawer tipping when installed properly.
Install the anti-tip block 14 13/16 inches above the installation opening floor
(where the unit will sit) for a standard installation or 14 5/8 inches for a flush
installation. The 6-inch Anti-Tip block must be provided by the installer. See
Figure 3 (standard installation) or Figure 4 (flush installation) and Figure 5. The
Anti-Tip block prevents serious injury that might result from spilled hot liquids.
If the MicroDrawer™ microwave oven is ever moved to a different location, the
Anti-Tip block must also be moved and installed. If the anti-tip block is to be anchored to the wall make certain that the screws
holding it penetrate into the structural members (studs) behind any covering such as drywall.
CAUTION
Make sure that the screws do not contact any wiring or plumbing that may be present in the wall.
WARNING
The unit can tip and cause spills and potential burns or other injuries if the anti-tip block is not installed correctly.
Figure 5
4"
(101.6 mm)
5" (127 mm)
Ubicación del
tomacorriente eléctrico*
Bloque
antivolcaduras
6"
(153 mm)
3 1/2"
(89 mm)