background image

CONTROL PANELS

MODELS: HDW, HTSW
ELECTRONIC TOUCH CONTROLS

A. Motor OFF button
B.

ON button and motor speed

selection button 1, 2, 3, 1,....

C. Speed 3 LED
D. Intensive 4th Speed LED
E.

Speed 1 LED

F.

Speed 2 LED

G. Intensive 4th speed ON

switch -  this speed will run
for 10 minutes, and then
return to previous setting,
including OFF.

H. Light OFF button
I.

Light ON button

Grease Filter Saturation 

LED

The 

flashing  LED

 marked 

D

reminds you when the grease filter
needs to be cleaned after 40 hours
use. Follow the instructions for
cleaning filters in this booklet.  Once
the grease filters have been cleaned,
reset reminder by pressing button

A

 for about 3 seconds until you hear

the signal (beep); the 

LED 

D

 will

now stop flashing.

MODELS: HGSW
MECHANICAL PUSH BUTTONS

MODELS: HCSW and HSW
ELECTRONIC PUSH BUTTONS

A. Motor OFF button
B. Motor ON button and speed

selector 1, 2, 3, 1.....

C. Speed 1 LED
D. Speed 2 LED
E. Speed 3 LED
F. Intensive 4th speed LED
G. Intensive 4th speed button -  this

speed will run for 10 minutes,
and then return to previous
setting, including OFF.

H. Light ON, OFF button

A

B

F G

E

D

H

C

O

1

2

3

a.

b.

c.

d.

e.

f.

A. Hood "ON" indicator light
B.

Light ON-OFF button

C. Motor OFF button
D. Motor speed button 1 (low)
E.

Motor speed button 2 (med)

F.

Motor speed button 3 (high)

Page 4

Summary of Contents for HCSW

Page 1: ...n Beach CA 92649 800 735 4328 ECO 71589 35 05 017F BSH Home Appliances Corp 1997 Litho in Italy 10 01 READ AND SAVE THESE INSTRUCTIONS CARE AND USE FOR WALL HOODS Turn Book Over for Installation Instr...

Page 2: ...turn hood ON when cooking on high heat or when flamb ing foods IMPORTANT SAFETY INSTRUCTIONS 3 Clean ventilating fans frequently Grease should not be allowed to ac cumulate on fan or filter 4 Use prop...

Page 3: ...est n cessaire Chauffer l huile lentement sur un positionnement bas moyen 4 Ne pas laisser la cuisini re sans surveillance pendant la cuisson 5 Utiliser toujours les batteries de cuisine et les usten...

Page 4: ...filtersinthisbooklet Once thegreasefiltershavebeencleaned reset reminder by pressing button A for about 3 seconds until you hear the signal beep the LED D will now stop flashing MODELS HGSW MECHANICAL...

Page 5: ...cool If new lights do not operate check fuses see page 7 Fuses and be surelightsareinsertedcorrectlybefore calling service OPERATING INSTRUCTIONS HOOD The blower should be turned on for about 5minute...

Page 6: ...SW HCSW36 42 Fig 3 Unscrew the light cover Remove the damaged light and replace with a new 12 Volt 20 Watt maximum halogenlightmadefora G 4 base Follow package directions and do not touch new light wi...

Page 7: ...Page 7 Fig 7...

Page 8: ...For All repair labor and replacement parts found to be defective due to materials and workmanship Service must be provided by a Factory Authorized Service Agency during nor mal working hours For a Se...

Page 9: ...ith this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at the service entrance and lock out panel before wiring this appliance Re...

Page 10: ...vice pour indiquer que l alimentation a t coup e pour l entretien C Le Travail d Installation et de C blage lectrique Doit tre Fait Par les Personne s Qualifi es Conform ment Tous les Codes Normes App...

Page 11: ...8 21 5 8 14 3 4 3 3 4 6 400 427 2 40W 220W 2 16A HSW30 37 25 5 8 33 42 1 2 30 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HSW36 42 25 5 8 33 42 1 2 36 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HTS...

Page 12: ...ht run or as few elbows as possible CAUTION Vent unit to outside of building only 2 Use flex ducting only to connect rigid duct directly to transitions 3 COLD WEATHER installations should have an addi...

Page 13: ...ll or using a stud finder Mark the center of the studs with a vertical line to the right and left of the marked fastener location Note Each 2 x 6 must span at least 2 studs side to side 7 Cutout drywa...

Page 14: ...e a gap of 1 minimum between top of transition and sheet metal duct and cover gap with a starting collar wrapped around duct and transition Locate collar screws so they fit into corner of duct cover S...

Page 15: ...anel Check lights and blower operation per Care Usesectionofthismanual Install filters 6 Install duct cover per Fig B Make sure to leave this manual for the home owner Alternate reduced ceiling height...

Page 16: ...ed 1 4 below the ceiling The resulting space on top of the chimney can be filled with a 1 4 thick piece of plywood cut to theinsidecrosssectionofthechimney cover and finished to match the ceiling Copy...

Reviews: