Page 2

vent to the attic or crawl space.

H. WARNING - TO REDUCE THE

RISK OF FIRE, USE ONLY
METAL DUCT WORK.

I.

Install this hood in accordance with
all requirements specified.

E. Due to size and weight of this unit

two installers are recommended.

F. When cutting or drilling into wall

or ceiling, do not damage electrical
wiring and other hidden utilities.

G. Ducted fans must always be

vented to the outdoors.  Do not

AVERTISSEMENT - POUR RÉDUIRE
LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE, OU DE LA BLESSURE
AUX PERSONNES, OBSERVER LE
SUIVANT:

ATTENTION:  SEULEMENT POUR
L’UTILISATION D’AÉRATION.  NE
PAS L’UTILISER POUR ÉPUISER LA
VAPEUR OU LES MATIÈRES
EXPLOSIVES OU DANGEREUSES.

A. Utiliser cet appareil seulement dans

la manière destinée par le fabricant.
Si vous avez des questions,
contacter le fabricant.

B. Avant l’entretien ou le nettoyage

de l’appareil, couper le courant au
tableau de service, et fermer à clef
la moyenne de débrayage de ser-
vice pour empêcher l’alimentation
d’être allumée par hasard.  Quand
la moyenne de débrayage de ser-
vice ne peut pas être fermée à clef,
attacher une étiquette au tableau
de service pour indiquer que
l'alimentation a été coupée pour
l'entretien.

C. Le Travail d’Installation et de

Câblage Électrique Doit Être
Fait Par les Personne(s)
Qualifiées Conformément à

Tous les Codes & Nor mes
Applicables, y Compris la Con-
struction Calculée à Feu.

D. L’écoulement comburant pour le

fonctionnement sûr du matériel
de la combustion du combustible
peut être affecté par le
fonctionnement de cet appareil.
Suivre la directive des fabricants
du matériel chauffant et les normes
de sécurité tel que ceux publiées
par l’Association du Protection de
Feu National (NFPA), et la Société
Américaine pour les Ingénieurs de
Chauffage, de Réfrigération et de
Climatisa- tion (ASHRAE), et les
autorités des codes locales.

E. Par suite de la dimension et le

poids de cet appareil, deux
installateurs sont recommandés.

F. En coupant ou en forant dans un

mur ou dans un plafond, ne pas
endommager le câblage  électrique
et des autres utilités cachées.

G. Les ventilateurs canalisés doivent

être toujours déchargés à
l’extérieur et vers le haut.  Ne pas
décharger au grenier ou au vide
sanitaire.

H. Pour réduire le risque d’incendie,

utiliser seulement le travail du
conduit métallique

.

I.

Installer ce capot conformé- ment
aux toutes exigences spécifiées par
le fabricant de votre cooktop/
cuisinière.

LES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES

Summary of Contents for HCSW

Page 1: ...n Beach CA 92649 800 735 4328 ECO 71589 35 05 017F BSH Home Appliances Corp 1997 Litho in Italy 10 01 READ AND SAVE THESE INSTRUCTIONS CARE AND USE FOR WALL HOODS Turn Book Over for Installation Instr...

Page 2: ...turn hood ON when cooking on high heat or when flamb ing foods IMPORTANT SAFETY INSTRUCTIONS 3 Clean ventilating fans frequently Grease should not be allowed to ac cumulate on fan or filter 4 Use prop...

Page 3: ...est n cessaire Chauffer l huile lentement sur un positionnement bas moyen 4 Ne pas laisser la cuisini re sans surveillance pendant la cuisson 5 Utiliser toujours les batteries de cuisine et les usten...

Page 4: ...filtersinthisbooklet Once thegreasefiltershavebeencleaned reset reminder by pressing button A for about 3 seconds until you hear the signal beep the LED D will now stop flashing MODELS HGSW MECHANICAL...

Page 5: ...cool If new lights do not operate check fuses see page 7 Fuses and be surelightsareinsertedcorrectlybefore calling service OPERATING INSTRUCTIONS HOOD The blower should be turned on for about 5minute...

Page 6: ...SW HCSW36 42 Fig 3 Unscrew the light cover Remove the damaged light and replace with a new 12 Volt 20 Watt maximum halogenlightmadefora G 4 base Follow package directions and do not touch new light wi...

Page 7: ...Page 7 Fig 7...

Page 8: ...For All repair labor and replacement parts found to be defective due to materials and workmanship Service must be provided by a Factory Authorized Service Agency during nor mal working hours For a Se...

Page 9: ...ith this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at the service entrance and lock out panel before wiring this appliance Re...

Page 10: ...vice pour indiquer que l alimentation a t coup e pour l entretien C Le Travail d Installation et de C blage lectrique Doit tre Fait Par les Personne s Qualifi es Conform ment Tous les Codes Normes App...

Page 11: ...8 21 5 8 14 3 4 3 3 4 6 400 427 2 40W 220W 2 16A HSW30 37 25 5 8 33 42 1 2 30 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HSW36 42 25 5 8 33 42 1 2 36 20 1 4 14 3 4 3 3 4 6 400 310 2 18W 220W 2 A HTS...

Page 12: ...ht run or as few elbows as possible CAUTION Vent unit to outside of building only 2 Use flex ducting only to connect rigid duct directly to transitions 3 COLD WEATHER installations should have an addi...

Page 13: ...ll or using a stud finder Mark the center of the studs with a vertical line to the right and left of the marked fastener location Note Each 2 x 6 must span at least 2 studs side to side 7 Cutout drywa...

Page 14: ...e a gap of 1 minimum between top of transition and sheet metal duct and cover gap with a starting collar wrapped around duct and transition Locate collar screws so they fit into corner of duct cover S...

Page 15: ...anel Check lights and blower operation per Care Usesectionofthismanual Install filters 6 Install duct cover per Fig B Make sure to leave this manual for the home owner Alternate reduced ceiling height...

Page 16: ...ed 1 4 below the ceiling The resulting space on top of the chimney can be filled with a 1 4 thick piece of plywood cut to theinsidecrosssectionofthechimney cover and finished to match the ceiling Copy...

Reviews: