4
Preferred
Location
of Conduit
Box
Figure 2- Cabinet Cutout - Wall Mounted Installation
Refer to dimensions for specific ovens on Page 5
FRONT VIEW
SIDE VIEW
FLOOR
LINE
F
G
Double Oven
Location of
Conduit Box
Exposed Edge
Must be a Finish-
Cut
D
Recommended
2" Diameter Hole (4.5
cm)
Frame
Overlap
(Top) 3/8"
(1, 0 cm)
Cabinet
Approx. 5" (13 cm)
2-1/2" (6, 4
cm)
Above
Unit
Side Frame
Overlap
5/8" Cabinet
(1, 6 cm)
A
Post Supports
Required Near
Back
H
❤
❤
E
C
B
Conduit Box May be Placed
Here
❤
❤
❤
2x4 Supports
CONDUIT BOX IS NOT
FURNISHED WITH UNIT
(Wall Stud)
The cabinet cutout dimensions for wall mounted
and under the counter installations are shown in
Figs. 2 and 3, respectively.
It is good practice, when oven is installed at the
end of a cabinet run, adjacent to a perpendicular
wall or cabinet door, to allow at least 1/4" space
between the side of the oven door and the wall/
door.
Wall Mounted Units
For oven support, install 2 x 4’s extending front
to back flush with the bottom and the side of the
opening.
The supporting base must be well secured to the
floor/cabinet and level with the floor line.
STEP 2: CABINET PREPARATION
O
V E N
P
OUNDS
K
ILOGRAMS
SE-series Single Oven
165
75
C-series Single Oven
210
95
CM Single Oven
240
109
S-series Double Oven
330
150
C-series Double Oven
355
161
CM Double Oven
370
168
NOTE
: The conduit box for double ovens
(SEC272, SECD272, SEC302, SECD302, C272,
C302, CM302, SEMW272 and SEM272) should be
located above the unit to facilitate connecting and
servicing. For single ovens (SEC301, C271, C301,
and CM301) the conduit box may be installed
either above or below the unit. If the conduit box
is installed below the unit, a 2" diameter hole or
space is required between the back wall and the
right rear of the 2 x 4 supports. See Figure 2.
When an oven is installed, the cabinet base must
be capable of supporting the oven weight as listed
below:
Wall Mounted Installation