Heater Settings

There are three separate options for heater operation in the 40000 Series Big Dipper.  Settings are enabled 

by moving the jumper to the correct position on the jumper block marked HEATER.

Simultaneous Heat Operation (Standard)

Units Ship with jumper in Position B, which results in Simultaneous Heater Operation meaning 

the Heater will activate anytime the motor is engaged.

Fluid Preheat Operation

To activate Fluid Preheat setting, move jumper to Position C on the jumper block using needle 

nose pliers.  In this setting, heater will activate prior to skim cycle, which will begin once the 

liquid temperature has reached 130º F or after a maximum of 2 hours has passed.  The heater 

will continue to operate under Thermistor control until skim cycle is complete.

No Heater Operation

To deactivate heater, move jumper to Position A.  In situations with low water turnover or 

grease production, a heater may not be necessary.  Contact a Thermaco representative before 

deciding to deactivate heater operation.  

AST Settings

The AST Settings only affect operation of the unit when the AST Solenoid is wired to the board.  This 

comes standard in the AST line of Big Dipper Units and the setting chosen determines how often and 

for how long the AST function operates.

2 Hour Interval (Standard for W-750-AST and W-1250-AST Models)

In this setting, used with W-750-AST and W-1250-AST Models, the AST Feature will operate for 

15 seconds every 2 hours, flushing incidental solids from the system.  The jumper will be placed 

on the lower two jumper pins to activate this setting.

24 Hour Interval (Standard for W-250-AST)

In this setting, used with the W-250-AST, the AST Feature will operate for 10 seconds every 24 

hours, flushing incidental solids from the system.  The jumper will be placed on the upper two 

jumper pins to activate this setting.

Board Settings for 40000 Series Big Dipper

NOTICE:

This document contains information on changing the settings inside the Center Lid Assembly of a 40000 

Series Big Dipper.  

DISCONNECT POWER TO CENTER LID ASSEMBLY BEFORE MAKING CHANGES. 

 

Contact a Thermaco representative before making changes to settings.  

Use needle nose pliers to remove and replace jumpers.