background image

18 

 

UNIT OPERATION 

 

FOR YOUR SAFETY READ BEFORE LIGHTING 
 

WARNING:

 If you do not follow these instructions exactly, a fire or explosion may result causing 

property damage, personal injury or loss of life. 

 
1.  When lighting the pilot, follow these instructions exactly. 
2.  BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor 

because some gas is heavier than air and will settle on the floor. 

3.  Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in 

or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Forced or 
attempted repair may result in a fire or explosion. 

4.  Do not use this appliance if any part has been under water. Immediately call a qualified service       

technician to inspect the appliance and to replace any part of the control system and any gas control 
which has been under water. 

 
WHAT TO DO IF YOU SMELL GAS 

  Open the window or door immediately. 

  Do not try to light any appliance. 

  Do not touch any electric switch, do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

  If you cannot reach your gas supplier, call the fire department.

 

LIGHTING INSTRUCTIONS 
 
Before Lighting: 

1.  Make sure the heater is properly installed and connected. Open the external safety shut off valve (not 

part of the heater) on gas inlet line to the heater. 

2.  Wait five (5) minutes to clear out air inside gas lines. Smell if there is any leakage. 

 

IMPORTANT: If you smell any gas, do not try to light any appliances, do not touch electrical 
switches or use any phone in the building. Shut off the valve on gas inlet line immediately and 
contact gas supplier from a neighbor’s phone. Follow gas supplier’s instructions. If you can’t 
reach the gas supplier, call the fire department. Only when you make sure there is no gas leakage, 
go to the next step.   
 
Note: 

During first seasonal use, gas smell is expected to be more noticeable than in standard operation. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for GLDF18T-VF

Page 1: ...some of our most popular products without requiring any adjustments Our product lines consist of vent free gas wall heaters a direct vent gas wall heater line kerosene and propane forced air heaters...

Page 2: ...reen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s of introduction of combustion air WARNING Keep the...

Page 3: ...clear and free of debris This will ensure enough air for proper combustion 6 If heater shuts off do not relight until you have provided fresh air from outside If heater keeps shutting off have it ser...

Page 4: ...ff system The ODS pilot shuts off the heater if there is not enough fresh air PULSE IGNITION SYSTEM This heater is equipped with a battery powered electric pulse igniting system No AC power supply req...

Page 5: ...priate for heater location The Air Shutter is pre set for Liquid Propane use If using Natural Gas see Air Shutter section of manual Unit successfully tested o Installed by Company ____________________...

Page 6: ...ompare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts Bef...

Page 7: ...roximately one 1 ounce 30 ml of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather than a primary heat source an entire h...

Page 8: ...f the aggregate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are cons...

Page 9: ...61 000 BTU Hr The space in the prior example is a confined space because the actual BTU hr used is more than the maximum BTU hr the space can support You must provide additional fresh air Your options...

Page 10: ...quired size of ventilation grills or ducts Ventilation Air from Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 inches of th...

Page 11: ...er creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke...

Page 12: ...tible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Installing Damper Clamp Remove all ashes or other...

Page 13: ...e log set is important as it improves the color and appearance of the flame The Air Door is located on the bottom of the log set heater So you will need to flip it over I recommend laying a cloth down...

Page 14: ...lide any further Once done you will tighten the screw on the cylinder then seal the air shutter cover again For more information please visit our website www thermablaster com You can contact us at 87...

Page 15: ...burner holes as this can lead to sooting and an overall drop in the performance of your heater Logs should be placed sequentially from lowest to highest as the numbering indicates There are grooves on...

Page 16: ...supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when co...

Page 17: ...1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off ope...

Page 18: ...WHAT TO DO IF YOU SMELL GAS Open the window or door immediately Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supp...

Page 19: ...is should be done slowly in one motion without stopping between positions Knob will only turn if you have a stable pilot light the heater will now operate normally 5 Adjust the Control Knob to your de...

Page 20: ...20 Figure 10 Control Panel Figure 11 Pilot System Figure 12 Pilot Blue Flame...

Page 21: ...bly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSl Your local computer store hardware store or home center may carry compressed air in a...

Page 22: ...your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet...

Page 23: ...when control knob is released Both control and igniter knobs are not fully pushed down Thermocouples are not heated enough External shutoff valve of gas supply is not fully opened Thermocouple connec...

Page 24: ...urning vapors from paint hair spray glues etc See IMPORTANT statement Gas leak See Warning Statement Low fuel supply Ventilate room Stop using odor causing products while heater is running Locate and...

Page 25: ...25 ILLUSTRATED PARTS Model GLDF18T VF...

Page 26: ...5 Bottom Strengthen strip No 2 12 NG Nozzle 36 Bottom Strengthen strip No 1 13 Air door washer 37 Air door shield 14 Air door rod 38 Sensor bulb bracket 15 Air door 39 Thermostat elbow 16 Burner 40 Th...

Page 27: ...ce Performed Service Date Please register your product online at www thermablaster com or send in the registration form below to our office at Reecon North America 2515 Liberty Ave Pittsburgh PA 15222...

Reviews: