10
Ultra-Aire 90H Installer’s & Owner’s Manual
11
Ultra-Aire 90H Installer’s & Owner’s Manual
FOR HVAC INSTALLER ONLY
5. DEH 3000 Digital Control
Installation Instructions
5.1 Specifications
Part # (P/N)
4026570
Model:
DEH 3000 Digital Control
Electrical:
24 VAC
Humidity Range:
10 – 95% RH
Humidity Accuracy:
+/- 5%
Output:
3 Amps 24 VAC
Relay Capacity
5 Amps
Temp Range/Accuracy
2%
Size
4.95" wide x 4.19" high
FOR HVAC INSTALLER ONLY:
5.2 Installation
This control panel must be installed in the conditioned space
and in accordance with all applicable codes and standards.
Follow the instructions below when installing and setting this
control.
5.2A Install Instructions
1. Separate the front panel from the back panel by
depressing the middle sections of the top and bottom of
the front panel.
2. Line the back panel up against the wall or flat surface
onto which it is to be mounted and drill in the appropriate
mounting holes.
3. Insert the screws and tighten down so they extend
approximately 1/8” from the back plate.
4. Align the back panel so that the control is level.
5. Tighten the screws to lock into position.
6. Make the electrical connections to the terminals on the
back panel as shown in the wiring diagram.
7. Reassemble the front to the back panel. Connect at the top
first, then at the bottom.
8. Test connections (see Section 2.6)
5.2B Wiring
WARNING:
DO NOT ALLOW THE YELLOW LEAD
FROM THE ULTRA-AIRE TO CONTACT THE RED OR WHITE LEADS
FROM THE ULTRA-AIRE OR DAMAGE TO THE TRANSFORMER
WILL RESULT
WARNING:
UNPLUG ULTRA-AIRE BASE UNIT
BEFORE WIRING CONTROL.
The installer must supply the wiring between the Ultra-Aire
and the control panel. Be sure to safely route the control wires
to prevent damage during installation. Be careful not to cross
the wires when connecting the Ultra-Aire and the remote
control panel or damage to the transformer may result.
The remote control of the Ultra-Aire is powered by a low
voltage circuit (24 VAC) and must
NEVER
contact or be
connected to a high voltage circuit. Some of the control wires
leaving the Ultra-Aire may not be used with certain control
panels and should be left safely disconnected with wire nuts
taped onto the stripped ends. Be sure to consult the electrical
schematic in this manual or on the front panel of the Ultra-
Aire before making the control connections.
Control Part No. 4026570