activate the high speed of the exhaust fan. These controls 
are to be UL listed with minimum electrical ratings of 2 amps 
inductive load at 125 VAC.

The prewired 7 day timer located on the Ultra-Aire Quiet Vent 
activates the low speed of the exhaust fan. The timer can be 
mounted remote from the Ultra-Aire Quiet Vent. This requires 
a double gang electrical box and 3 conductors plus ground 
to extend connections to the timer from the Ultra-Aire Quiet 
Vent.

A 4" junction box cover is used to cover the timer opening on 
the Ultra-Aire Quiet Vent.

 

WARNING: To reduce the risk of fire, 

electric shock, or injury to persons, observe 

the following:

A. Use this unit only in the manner intended 

by the manufacturer. If you have questions, 

contact the manufacturer.

B. Before servicing or cleaning unit, switch 

power off at service panel and lock service 

disconnecting means to prevent power from 

being switched on accidentally. When the 

service disconnecting means cannot be 

locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

 

CAUTION: For general ventilating use 

only. Do not use to exhaust hazardous or 

explosive materials and vapors.

3. Operation
3.1 Using the Timers

1. Setting The 7-Day Timer

Rotate the timer dial until the white pointer indicates the 
correct time of day. Each segment moved toward the 
dial center represents 2 hours of low speed exhaust fan 
operation. Typically, the timer is set to operate during the 
time of occupancy. If additional ventilation is required to 
control moisture and odors, additional spades can be moved 
in. If the home becomes too dry, decrease the hours of low 
speed operation.

3.2. Using Remote Timers

Estimate the ventilation time required and set it on the timer. 

Activate the timer whenever moisture or odors are generated 
in the room. If timers are not available locally, they may be 
ordered with the Ultra-Aire Quiet Vent.

3.2 Adjusting the Amount of Ventilation

The amount of air removed from the home depends on the 
restrictions in the duct system and the amount of time the 
system operates. If more or less ventilation is required the 
7-day timer can be set for more or less low speed operation. 
The air flow can be reduced by installing a duct damper in 
the exhaust duct of the Ultra-Aire Quiet Vent.

By partially closing the damper, the CFM of stale air removed 
from the house can be reduced. Figure 4 indicates air flow 
and power consumption versus static duct pressure.

4. Maintenance
4.1 Cleaning the Blower Screen

WARNING: Disconnect the appliance from the power 

supply before cleaning the blower screen.

A coarse screen covers the blower inlet port located inside 
the Ultra-Aire Quiet Vent cabinet. Vacuuming the screen is 
recommended every six months. Remove the 4" x 4" cover 
on the side of the Ultra-Aire Quiet Vent cabinet for access 
(See Fig. 1).

5 Service

 

CAUTION: Requires a qualified service 

person because electrical shock hazard is 

present.
5.1 Circuit Breaker Trips

Check For Short In Wiring:

FOR HVAC INSTALLER ONLY

5

Ultra-Aire Quiet Vent Installer’s & Owner’s Manual

0

50

100

150

200

250

300

350

.1 .2 .3 .4 .5 .6 .7 .8 .9          

Air Flows And Watts At Various Pressures

CF HIGH SPEED

WATTS HIGH SPEED

WATTS LOW SPEED

CF LOW SPEED

Summary of Contents for Quiet-Vent Ventilation System

Page 1: ...680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales thermastor com TS 174B INSTALLER S OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER P N 4019663 Serial No ________________________ Install Date ___________ Sold by ...

Page 2: ... reduce the risk of fire electric shock or injury to persons observe the following A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Foll...

Page 3: ... from the Ultra Aire Quiet Vent see paragraph F In cold climates the unit should be located in a heated space to prevent condensation from forming inside the cabinet A basement or utility room is an ideal location If the Ultra Aire Quiet Vent and its ducting must be located in a unheated space in a cold climate they must be insulated to prevent condensation from forming in the system If the Ultra ...

Page 4: ... stale air connect a six inch insulated flexible duct from the outlet of the Ultra Aire Quiet Vent to a dampered six inch wall cap If the length of the exhaust duct exceeds 50 ft an 8 duct should be used All the ducts must be insulated when they are located in non heated space in a cold climate Flexible duct can be spliced by threading the ends of the ducts into each other 3 turns To reduce leakag...

Page 5: ...ired to control moisture and odors additional spades can be moved in If the home becomes too dry decrease the hours of low speed operation 3 2 Using Remote Timers Estimate the ventilation time required and set it on the timer Activate the timer whenever moisture or odors are generated in the room If timers are not available locally they may be ordered with the Ultra Aire Quiet Vent 3 2 Adjusting t...

Page 6: ...the segments on the 7 day timer are moved to the center of the dial thus calling for low speed ventilation If the blower does not run with the segments in and the optional controls off check for voltage between timer terminal 5 and ground If terminal 5 does not have voltage the timer is defective If terminal 5 has voltage and relay terminal 5 does not have voltage the relay is defective If relay t...

Page 7: ...y the period of time if any that the Ultra Aire Quiet Vent is out of service while awaiting covered warranty service UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Ultra Aire Quiet Vent VENTILATING SYSTEM OR ANY PART THEREOF ALL OTHER WARRANTIES IMPLIED BY LAW INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL ALSO EXPIRE ALL WARRANTIES MADE BY THERMA STOR LLC ARE ...

Page 8: ...any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680 Madison WI 53708 Phone 608 222 5301 Fax 608 222 1447 Web www thermastor com Email sales thermastor com Ultra Aire Quiet Vent Installer s Owner s Manual ...

Reviews: