background image

9

www.UsePhoenix.com • [email protected]

Toll-Free 1-800-533-7533

Phoenix R200 50Hz Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC
4201 Lien Rd
Madison, WI 53704
Telephone: 1-800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix R200 50Hz 

dehumidifier, and may not be assigned or transferred.

Year One:

 Therma-Stor LLC warrants that, for one (1) year the Phoenix R200 50Hz dehumidifier 

will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its 
option, repair or replace the defective part(s), free of any charge.

Year(s) Two Through Five:

 Therma-Stor LLC further warrants that for a period of five (5) years, the 

condenser, evaporator, and compressor of the Phoenix R200 50Hz dehumidifier will operate free 
of any defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace 
the defective part(s), provided that all labor and transportation charges for the part(s) shall be 
borne by the end-user.

Year(s) One Through Seven:

 Materials and workmanship of the housing are covered.

End-User Responsibilities: 

Warranty service must be performed by a Servicer authorized 

by Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an 
authorized Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-
Stor Service Department, which will then arrange for covered warranty service. Warranty service 
will be performed during normal working hours.
The end-user must present proof of purchase (lease) upon request, by use of the warranty 
card or other reasonable and reliable means. The end-user is responsible for normal care. 
This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack 
of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or 
installation, accident, acts of nature or any other cause beyond Therma-Stor LLC’s reasonable 

control.

Limitation and Exclusions:

 If any Phoenix R200 50Hz Dehumidifier part is repaired or replaced, 

the new part shall be warranted for only the remainder of the original warranty period applicable 
thereto (but all warranty periods will be extended by the period of time, if any, that the Phoenix 
R200 50Hz Dehumidifier is out of service while awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX R200 
50Hz DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, 
INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO 
EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM 
MAY BE MADE AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT 
SHALL THERMA-STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR 

REPLACEMENT OF ANY PHOENIX R200 50Hz DEHUMIDIFIER OR PART THEREOF BE LIABLE 

UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES 

INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS 

AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR 

PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not 
allow the exclusion or limitation of incidental or consequential damages, so one or both of these 
limitations may not apply to you. 

Legal Rights:

 This warranty gives you specific legal rights, and you may also have other rights 

which vary from state to state.

Summary of Contents for Phoenix R200

Page 1: ...oping Handle A heavy duty retractable handle for ease of transport and reduces space for storage and stacking Recessed 30 cm Wheels For greater maneuverability on the job site and efficient storage Ro...

Page 2: ...arts and Labor 2nd 5th year 100 of sealed refrigeration system parts Dimensions Width 51cm Depth 51cm Height 85cm Weight 47kg U S Patent 7 246 503 3 Operation Place dehumidifier inside structure place...

Page 3: ...ucting to the wire duct collar by inserting the plastic duct end through the collar center and rolling the duct end outward to overlap the outside of the collar The duct and collar may then be quickly...

Page 4: ...MPORTANT DO NOT operate the unit without the filter or with a less effective filter as the heat exchanger and coils inside the unit could become clogged and require disassembly to clean 4 2 Storage an...

Page 5: ...lugged or no power to outlet 2 Defective control board 3 Loose connection in internal wiring No dehumidification neither hour meter display nor compressor run with POWER button ON 1 Defective control...

Page 6: ...rol housing grommet Figure 8 Picture of the float safety switch 6 Detach thermistor from control board jumper 7 Reassemble thermistor and dehumidifier using the above procedure in reverse 5 5 Condensa...

Page 7: ...3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 9 Wiring diagram 7 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 6 Options Accessories 4024750 Inta...

Page 8: ...13 Cord 1 4028256 14 Control Board 1 4028255 15 Capacitor Compressor 30 F 1 4033032 02 16 Capacitor Impeller 4 F 1 4033031 01 17 Thermistor 1 4031279 18 Handle lever 1 4026350 Description Qty Part No...

Page 9: ...he end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorize...

Reviews: