8 Service Parts

Item 

Description 

Qty 

Part No.

1  

Top Cover 

1  

4031258

2  

Filter, 12” x 12” x 1” MERV 7 

1  

4026315

3  

Impeller, Air Mover  

1  

4034477

Evaporator Coil  

1  

4031253

5  

Condenser Coil  

1  

4031254

6  

Condensate Pump  

1  

4034496

7  

Capacitor, Compressor, 35 μF   1  

4033032-03

8  

Compressor  

1  

4030483

Thermistor Probe 

1  

4034716-02

10  

Capacitor, Impeller, 6.0 μF  

1  

4033031-03

11  

Hex Bolts,  1/4”–20 x 1.25”  

6  

1154012

12  

Handle Bar 

1  

4031267

13 

Handle Grip 

4031268

14  

Wheel, 12”, Black 

2  

4026851

15  

Cotter Pin  

2  

1284404

16  

Hub Cap, Wheel, Black 

2  

4027138

17 

Handle Knob, Lanyard  

4033372

18  

Control Board  

1  

4034457

19  

Power Cord  

1  

4032297

Items listed are not shown

Description  

Qty  

Part No.

Hose (1/4” ID x 33’ long)  

1  

4024916

Coupling Body, 1/4” Tube  

1  

4024910

Coupling Insert, 1/4” Tube  

1  

4027277

Exhaust Grill  

1  

4026308

Wire Duct Collar  

1  

4026309

1

2

3

4

5

6

7

8

9

10

11

12

13

14 15

16

17

18

19

Summary of Contents for Phoenix R150 LGR

Page 1: ...for deep drying Energy Efficiency Removes 75 pints at AHAM while drawing only 5 5 amps Patented Bypass Technology Extends operating range to 110 F 150 CFM Optimized process air speeds drying and prov...

Page 2: ...MERV 8 Duct Options Outlet 10 Lay Flat Warranty Five years 1st year 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 30 high x 20 wide x 17 deep Weight 82 lbs Pate...

Page 3: ...l continue to run causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increases the evaporator temperature will rise an...

Page 4: ...that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Ser...

Page 5: ...compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents im...

Page 6: ...lace the pump hose wiring bolts and housing in the reverse order 6 Options Accessories 4026315 Air Filter Pleated 12 x 12 x 1 MERV 8 4025568 Air Filter Pleated 12 x 12 x 1 MERV 11 4024935 Lay Flat Duc...

Page 7: ...BLK 16 WHT 2 WHT 7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WHT 6 CONTROL BOARD RUN CAP FAN MOTOR PUMP SAFETY NO NC FLOAT WHT PUMP FAN LEVEL SWITCH THERMISTOR 1 LINE 2...

Page 8: ...1 4030483 9 Thermistor Probe 1 4034716 02 10 Capacitor Impeller 6 0 F 1 4033031 03 11 Hex Bolts 1 4 20 x 1 25 6 1154012 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 Black 2 4026851 15...

Page 9: ...e end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized...

Reviews: