background image

5

www.usephoenix.com • [email protected]

Toll-Free -800-533-7533

Specifications subject to change without notice.

1

6

4

0

X

Y

PART NO.          REV.

4027332       A

230 VAC

60 HZ, 1 Ph

1

0

4

6

Yellow

Low Voltage Schematic

High Voltage Schematic

Made in U.S.A

Therma-Stor LLC, Madison, WI 53708

800-533-7533 or Local 608-222-5301

www.thermastor.com

Blower

Capacitor

Blower

Relay

Heater

Blower

Bro

wn

Transformer

5200 Watt

10

Contactor

#1

Contactor

#2

Orange

Blue

50 AMP

Receptacle

Blue

Black

Red

Black

Blac

k

3800 Watt

14

Contactor #2

L1

Blue

Blower

Black

230 V

24 V

Optional

Thermostat

Master

Power Switch

Pressure

Switch

140°

Thermal 

Cut-Out

Hi/Low

Power

Switch

Blower Relay 

Coil

Hour

Meter

Contactor #2

Coil

Contactor #1

Coil

Transformer

Brown

Blower

Capacitor

Blower

Relay

L2

5200 Watt

Element

Contactor #1

3800 Watt

Element

Hi-Low

Power Switch

Blower Relay

Thermostat

Connection (Optional)

Brown

Transformer

Hour Meter

Master Power 

Switch

Yellow

Contactor

#1

Contactor

#2

140°

Thermal

Cut-Out

Pressure

Switch

Yellow

Yellow

Red

Red

Red

Or

ange

Orange

Blue

Blue

Blue

Black

Blac

k

Black

6 Wiring Diagram

Summary of Contents for Phoenix FireBird

Page 1: ...ing the 30 amp setting the FireBird produces 18 000 BTU s giving a 46 F temperature rise Internal temperature cutouts prevent the FireBird from overheating an area while the FireBird s externally loca...

Page 2: ...er Return to authorized service facility for adjustment or repair Device not intended for use directly in an area where it may fall into a bathtub or other water container DO NOT run cord under carpet...

Page 3: ...ecreases airflow which can increase outlet temperatures by up to 20 additional degrees F Install the 12 duct adapter by lining up the notch of the adapter with the rivet on the cabinet then push in th...

Page 4: ...nts together provide high power operation The heating elements and the blower are operated by a 24VAC control circuit and a number of relays and contactors For safety there is an air pressure switch t...

Page 5: ...Blue 50 AMP Receptacle Blue Black Red Black Black 3800 Watt 14 Contactor 2 L1 Blue Blower Black 230 V 24 V Optional Thermostat Master Power Switch Pressure Switch 140 Thermal Cut Out Hi Low Power Swit...

Page 6: ...ermal Switch 1 4026898 5 Pressure Switch 1 4027305 6 Blower Relay 1 4022484 7 5mf Capacitor 1 4027315 8 Heating Element 1 4027317 9 Flanged 50A Inlet 1 4027308 10 Master Power Switch 1 4027310 11 Hour...

Page 7: ...reasonable control Limitation and Exclusions If any Phoenix FireBird part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable the...

Reviews: