Owner’s Manual   —   Phoenix FireBird

Installation, Operation and Service Instructions

Important Instructions – Read and Save These Instructions

The FireBird portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed to work with 
standard 30 or 50 amp power sources—select the setting using the HIGH/LOW switch. 
At the 50-amp setting, the FirebBird produces 3,000 BTU’s—thats 360 CFM with a 80°F temperature rise. In an area 
with below freezing temperatures the FireBird can produce 360 CFM of air over 00 degrees. Using the 30-amp setting the 
FireBird produces 8,000 BTU’s—giving a 46°F temperature rise. Internal temperature cutouts prevent the FireBird from 
overheating an area while the FireBird’s externally located thermostat terminals provide a means to control the heat from 
anywhere in the drying space.

The Phoenix FireBird

•  ETL Certified, UL Listed
•  30 or 50 Amp operation (18,000 BTU/31,000 BTU) 

30 Amp

 = 24 Actual Amp Draw and 46ºF Temperature Rise 

50 Amp

 = 40 Actual Amp Draw and 80ºF Temperature Rise

 

Two 8’ Power Cords  
(1 dryer, 1 range)

 included with unit

•  360 CFM
•  Multiple air filter options

  Standard MERV-, MERV-4

•  Multiple ducting options

  2” intake, 2” supply

•  Detachable 12” Duct Collar stores in lid with room for 

power cords

•  Stainless steel cabinet

Specifications subject to change without notice.

TS-407

Revised 12/07

PO Box 8680 • Madison, WI 53708

Summary of Contents for Phoenix FireBird

Page 1: ...ing the 30 amp setting the FireBird produces 18 000 BTU s giving a 46 F temperature rise Internal temperature cutouts prevent the FireBird from overheating an area while the FireBird s externally loca...

Page 2: ...er Return to authorized service facility for adjustment or repair Device not intended for use directly in an area where it may fall into a bathtub or other water container DO NOT run cord under carpet...

Page 3: ...ecreases airflow which can increase outlet temperatures by up to 20 additional degrees F Install the 12 duct adapter by lining up the notch of the adapter with the rivet on the cabinet then push in th...

Page 4: ...nts together provide high power operation The heating elements and the blower are operated by a 24VAC control circuit and a number of relays and contactors For safety there is an air pressure switch t...

Page 5: ...Blue 50 AMP Receptacle Blue Black Red Black Black 3800 Watt 14 Contactor 2 L1 Blue Blower Black 230 V 24 V Optional Thermostat Master Power Switch Pressure Switch 140 Thermal Cut Out Hi Low Power Swit...

Page 6: ...ermal Switch 1 4026898 5 Pressure Switch 1 4027305 6 Blower Relay 1 4022484 7 5mf Capacitor 1 4027315 8 Heating Element 1 4027317 9 Flanged 50A Inlet 1 4027308 10 Master Power Switch 1 4027310 11 Hour...

Page 7: ...reasonable control Limitation and Exclusions If any Phoenix FireBird part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable the...

Reviews: