2

2. Features:

Permanent ON/Off facility. This enables the heater 
under control to be turned Off when alternative 
methods of heating are available, or during a 
holiday period. It also enables the heater to be 
permanently turned ON.
Shortest switching time of 15 minutes increasing 
in 15 minute steps.
Up to 48 programmes per day.

3. Installation:

We recommend that this unit be fitted by a 
qualified electrician. Install in accordance 
to wiring and current building regulations. 
Please read the instructions carefully. If in 
any doubt contact the Timeguard Helpline.
Important: Switch off mains electricity 
before commencing work.

Remove the terminal cover. fix the unit to the wall 
with the mounting screws provided. fix the top 
screw first and leave 2.5mm proud, place the key 
hole in the top of the product over the screw head 
and slide down. Then mark and drill the lower 
fixing. Secure unit to the wall.
The wiring can enter through the rear knock outs 
or the cable entry ports provided. If the wiring is 
not through the knock outs, use the cable clamps 
provided to secure the cables.
Connect the installation wiring to the terminals 
provided, according to the legend on the terminal.

Note: the NTT05 is supplied with a wire link 
in place. This should not be removed unless 
voltage free contacts are required. If the 
link is removed then the output light will 
no longer function.