500W “C” Class Halogen 

Floodlight with 240º 

PIR Control

Model: MLBPRO500C (Black)

Model: MLWPRO500C (White)

Summary of Contents for Time Guard MLBPRO500C

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 500W C Class Halogen Floodlight with 240º PIR Control Model MLBPRO500C Black Model MLWPRO500C White ...

Page 2: ...contact problems Plug in terminal block for quick and easy wire free connection and convenient replacement of the light bulb Adjustable lens giving a 240º outer zone from 3 to 16m and a 360º inner zone giving comprehensive coverage within a 3m radius circle Multi segmented lens shields included for blocking zones within a detection area Each segment blocking a detection angle of 10º Rotatable sens...

Page 3: ...Off the Mains Power Supply Before Installation The MLB WPRO500C can be either wall mounted or corner mounted with an adapter included with the product See Fig 5 Fig 5 Wall Mount Fig 5a Corner Mount Fig 5b Corner Mounting Adapter See section B Fig 6 Fig 7 A Installation Procedure a Read the instruction manual before installing the MLB WPRO500C b Make sure the mains power supply has been disconnecte...

Page 4: ...ures 3 Locate one of the bulb contacts onto one of the fitting contacts and push back the contact spring at the other end inserting the bulb contact into its fitting contact check that the bulb contacts at each end are properly located and that there is reasonable pressure on the bulb contacts See Fig 10 4 Tighten the floodlight cover screws firmly to ensure weatherproof rating e Make backplate holes ...

Page 5: ...e horizontally rotated 60º to right or left As shown in Fig 20 b Adjustment of the floodlight You can adjust horizontally right or left 45º See Fig 21 c The Adjustment of LUX METER and TIME The MLB WPRO500C has three adjustable knobs LUX METER and TIME on the underside of the sensor head The LUX knob can be set to allow the MLB WPRO500C to operate at any light level between full daylight and almost...

Page 6: ...any ambient light level and the light will go on for about 6 seconds after each detection While the light is ON and for 2 seconds afterwards the person carrying out the walk must remain stationary before continuing on the path shown in Fig 25 How to adjust your desired detecting area s 1 Follow Fig 25 and start the Walk Test across the detection zones to check that the light under control comes on...

Page 7: ...here are any white or reflective surfaces in the detection area and adjust the sensor to a different direction or adjust the lens shield 2 The sensor is more sensitive in winter Please check again when the temperature gets back to normal Rain snow and storm can create big temperature changes that activate the sensor False triggering can be minimised by installing the sensor in a protected location ...

Page 8: ...up to 200W can be connected Power Consumption Less than 1W Quiescent Detection Angle 10º 240º adjustable for the outer zone detecting range from 3 to 16m 360º for the inner zone detection range within a radius of approx 3m Light ON Time Adjustable from about 6 seconds to 12 minutes METER range restriction Adjustable 3 16m LUX Adjustable ambient light level control Adjustable Angle Sensor Head Left...