background image

5

Product overview

Type of 

installation

Channel Operating 

voltage

Colour

Type

Item 

number

Ceiling 

installation

Light 

230V AC

White

theRonda 

S360 -100 DE 

WH

2080560

Ceiling 

installation

Light 

230V AC

Grey

theRonda 

S360-100 

DE GR

2080561

Ceiling 

installation

Light 

230V AC

Special colour 

in accordance 

with customer 

information

theRonda 

S360-100 

DE SF

2080563

Ceiling 

installation

Light 

230V AC

White

theRonda 

S360-100 AP 

WH

2080550

Ceiling 

installation

Light 

230V AC

Grey

theRonda 

S360-100 

AP GR

2080551

Ceiling 

installation

Light 

230V AC

Special colour 

in accordance 

with customer 

information

theRonda 

S360-100 

AP SF

2080553

Troubleshooting 

Fault

Cause

Light does not switch 

on if presence is 

detected and in 

darkness

Lux value is set too low; light was switched off 

via theSenda S; person not within detection area; 

obstruction(s) interrupting detection; time delay 

set too short

Light does not switch 

off and/or light 

switches on spontane-

ously when no one is 

present 

Wait for time delay;

thermal sources of interference in the detection 

area: fan heaters, incandescent lamps/halogen 

spotlights, moving objects (e.g. curtains hanging in 

open windows); 

Load (EBs, relays) not cleared

Error flashing  

(4 x per second)

Error in self-test; 

Device not properly functional!

LED display

LED

Description

Flashing at 

1 second 

intervals

The presence detector is in the start-up phase.

Flickering 

for 2s

The command sent from the remote control via infrared 

was accepted by the presence detector.

Lighting up 

briefly

The command sent from the remote control via infrared 

was rejected by the presence detector. The command is 

not valid. Check the detector type or parameter selected 

in the "SendoPro".

Fast flashing

Error flashing; The presence detector has found an error.

Lights up 

or flickers 

irregularly

The presence detector is in detection area test mode or 

"LED display movement" is activated. The LED displays 

detection of movement.

Guarantee

Theben HTS presence detectors are manufactured with 

the utmost care using state-of-the-art technology and are 

quality-tested. Theben HTS AG therefore guarantees perfect 

operation when used correctly. Should a fault occur, Theben 

HTS AG will fulfil the guarantee within the scope of the gene-

ral terms and conditions.

Please note in particular:

 

that the guarantee period lasts 24 months from the date 
of manufacture. 

 

that the guarantee is invalidated if you, or a third party, 
make changes to or undertake repairs on the devices.

 

that, insofar as the presence detectors are connected 
to a software-controlled system, the guarantee for this 
connection is only valid when the indicated interface 
specification is complied with.

We undertake to repair or replace as quickly as possible 

all components of the delivered device that have become 

defective or unusable through demonstrably poor material, 

faulty construction or incomplete delivery up to the end of the 

guarantee period. 

Returns
In the event of a guarantee claim, please return the device to 

the relevant dealer together with the delivery note and a brief 

description of the fault.

Industrial property rights
The design as well as hardware and software of these devices 

are protected by copyright.

Dimensions diagrams

theRonda S360-100 DE

theRonda S360-100 AP

Summary of Contents for theRonda S360-100 DE GR

Page 1: ...r indoor installation The presence detector is exclusively intended for the use as con tractually agreed between the manufacturer and the user Any other use is considered to be unacceptable The manufacturer does not accept liability for any resulting damages 4 Operation The presence detector is primarily used in passageways such as corridors stairs toilets basements and garages as well as in homes...

Page 2: ...nce detector is designed for the operation of fluo rescent lamps compact fluorescent lamps halogen incande scent lamps and LEDs The maximum number of switchable lights is restricted due to the high inrush current levels of the EBs and LED drivers The use of an external contactor helps with large loads All switched loads must be properly suppressed 6 Installation Ceiling installation Installation i...

Page 3: ...d brightness value will be accepted as the brightness switching value Values out side the permitted range will automatically be set to the appropriate limit value x x Switching light Lighting group can be swit ched on and off x x Presence test On Off x x Restart Restart detector x x Factory settings Set all parameters and set tings to factory setting x Brightness switching value Channel A light Th...

Page 4: ...t presence detec tion and wiring Presence test mode can be activated with the SendoPro 868 A management remote control and with the theSenda P installation remote control Setting test mode detection area with remote control The detector goes directly into test mode when the test mode is set via the remote control y y Every movement is indicated by the LED y y When movement occurs the light switch ...

Page 5: ...rom the remote control via infrared was rejected by the presence detector The command is not valid Check the detector type or parameter selected in the SendoPro Fast flashing Error flashing The presence detector has found an error Lights up or flickers irregularly The presence detector is in detection area test mode or LED display movement is activated The LED displays detection of movement Guaran...

Page 6: ... 12 Contact Theben HTS AG Im Langhag 7b 8307 Effretikon SWITZERLAND Phone 41 52 355 17 00 Fax 41 52 355 17 01 Hotline Phone 41 52 355 17 27 support theben hts ch www theben hts ch All countries except Switzerland Theben AG Hohenbergstraße 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de www theben de ...

Reviews: