Page | 30
The segmented bar graph now indicates that the night break is active. The time segment
when the shop window lighting is on is no longer active for the whole night, but is
interrupted from
11:00 PM to 5:00 AM.
Note:
The DAYTIME SWITCH-ON is performed according to the same principle as the NIGHT BREAK
described above.
8.1.2. STANDARD: Checking switching times
If you want to check whether the switching times have been correctly programmed, you can view all
switching times.
For example, if you wish to check the switching time for the previously programmed
Friday:
Press the MENU button to open the main menu from auto mode.
Confirm the PROGRAM menu by pressing OK.
Press the OK button.
Press button ► once until CHECK appears on the display and press OK to confirm.
Now the week days and corresponding switching times are displayed in chronological order on the time
bar, starting with the first week day (e.g. Monday). If no switching times are saved, EMPTY is faded in.
The buttons ◄ and ► (+/-) can be used to scroll through the saved switching times on the time bar:
… and so on.
All programmed switching times are shown individually for each day. Should the switching occur on
several days at the same time, the complete week day block is displayed and the respective week day
number (Monday = 1, Tuesday = 2, etc.) flashes.
Summary of Contents for SELEKTA 170 top2
Page 1: ......
Page 10: ...Page 10 2 Display and operation 2 1 General SELEKTA top2...
Page 11: ...Page 11 SELEKTA top3 2 2 Operation...
Page 99: ...Page 99...
Page 103: ...Page 103 A graphical switching time is edited in the list view...
Page 108: ...Page 108...
Page 112: ...Page 112 You can now send various direct commands to the device from the overview screen...