1.  Basic safety information

¾

¾

Connection and installation should only be carried 

out by a qualified electrician!

¾

¾

Before installation/dismounting, disconnect the 

power supply!

NOTE

 

The clock thermostat conforms with EN 60730-2-9 if 
correctly installed

 

Corresponds to type 1 STU in accordance with IEC/EN 
60730-2-7

 

Operation and programming only via 

RAMSES BLE 

app

 

With external input (SELV, programmable)

2.  Proper use

 

Heating control for time-dependent monitoring and 
control of room temperature in single-family houses, 

offices etc. 

 

Use in dry rooms with normal levels of domestic 
cleanliness 

Disposal

¾

†

Dispose of device in environmentally sound manner

3.  Installation

Mounting the clock thermostat

Electrostatic discharge!

 

Caution, sensitive electronic components! 

 

When fitting, observe ESD safety measures (elect

-

rostatic discharge).

 

!

Position the clock thermostat on an internal wall, at 

about eye level. 

 

!

Avoid drafts or heat emission.

 

 

L

For wall mounting

¾

†

Attach the mounting plate above the wall outlet of the 

OpenTherm line 

.

¾

†

Engage and wire the circuit board carrier 

.

¾

†

First, hook in the upper part of the clock thermostat on top, 

then engage 

¾

†

Put on the cover 

.

Dismounting the clock thermostat

¾

†

Using a screwdriver, loosen the front panel at the two side 

and bottom openings 

.

¾

†

Then release the catches on the left and right and remove 

the upper part of the housing 

.

¾

†

Loosen the plug-in connectors and press the circuit board 

carrier together at the top and bottom 

.

¾

†

Remove the circuit board carrier through the front.

4.  Connection

 

The power supply from the thermostat to the boiler is 

provided via OpenTherm.

 

The two-wire connection (OpenTherm) is not polarised, 

i.e. the wires can be connected to the boiler as required.

 

!

Disconnect the boiler from mains supply before connec-

ting the thermostat.

 

!

Faulty connections will damage the device.

 

!

Without interference, the bus line can be extended up to 

50 m.

 

!

In order to eliminate the possibility of EMC interference, 
always lay the feed of the supply voltage separate from 

the mains cables.