background image

1

RAMSES BLE OT

8509150

307347

Clock thermostat

EN

1. Basic safety information  3
2. Proper use 

3

Disposal 3

3. Installation 

4

Mounting the clock thermostat 4
Dismounting the clock  

thermostat 6

4. Connection 

6

Terminal layout   

7

5. Manual setting at the clock 

thermostat 7

Summary of Contents for 8509150

Page 1: ...ock thermostat EN 1 Basic safety information 3 2 Proper use 3 Disposal 3 3 Installation 4 Mounting the clock thermostat 4 Dismounting the clock thermostat 6 4 Connection 6 Terminal layout 7 5 Manual s...

Page 2: ...Pairing 8 3 Reset 8 6 Settings and functions operation via Theben app 9 Is my smartphone BLE capable 9 RAMSES BLE app 9 Connecting clock thermostat and smartphone via app pairing 10 Program 12 Info 1...

Page 3: ...9 if correctly installed Corresponds to type 1 STU in accordance with IEC EN 60730 2 7 Operation and programming only via RAMSES BLE app With external input SELV programmable 2 Proper use Heating con...

Page 4: ...lectrostatic discharge Caution sensitive electronic components When fitting observe ESD safety measures elect rostatic discharge Position the clock thermostat on an internal wall at about eye level Av...

Page 5: ...Attach the mounting plate above the wall outlet of the OpenTherm line Engage and wire the circuit board carrier First hook in the upper part of the clock thermostat on top then engage Put on the cove...

Page 6: ...ier through the front 4 Connection The power supply from the thermostat to the boiler is provided via OpenTherm The two wire connection OpenTherm is not polarised i e the wires can be connected to the...

Page 7: ...t 1 OT 2 OT 3 ext input 4 ext input 5 Manual setting at the clock thermostat Button with LED display for setting Comfort mode green LED on ECO mode green LED off By using the button the following func...

Page 8: ...phone tablet paired for 5 min green LED flashes If pairing is successful the LED goes out Delete pairing Press the button for 6 s All connections saved in the RAMSES BLE OT pairing will be deleted red...

Page 9: ...load Bluescan app for Android and iOS The app can be used to check whether a device is BLE capa ble or not RAMSES BLE app Set temperature adjustable in increments of 0 2 C 2 C 30 C Selection of OpenTh...

Page 10: ...k selection Eco mode until the next switching time Connecting clock thermostat and smart phone via app pairing The clock thermostats can be programmed using an app from Android 4 3 iOS 5 on a mobile e...

Page 11: ...device and press ok Enter the name for RAMSES BLE OT e g living room Confirm with ok RAMSES BLE OT is now paired Each time when rest arting the app a connection will be established This takes several...

Page 12: ...ater program in case of a heating system using domestic water Programs P1 P3 can be set edited or deleted A maximum of 24 switching times can be set per pro gram up to a total of 42 L LDuring programm...

Page 13: ...Activation After a holiday program has been created via the app the clock thermostat receives the following information active not active Start date and end date with time Room set temperature during...

Page 14: ...14 Info L LThe information in this submenu vary depending on the connected boiler With Info temperature flame set flow etc can be queried The functions change depending on the connected heating system...

Page 15: ...gs A window will open L LThe functions in this submenu have to be set by the quali fied electrician In the settings language temperature comfort eco frost wall compensation optimisation chimney sweep...

Page 16: ...d and actual room temperature might occur This difference can be corrected by using the wall compensation 2 Setting the controller The clock thermostat can be used depending on the set heating as room...

Page 17: ...nge I share 1 20 integral share in minutes Integral share small quick adjustment of the control deviation Integral share large slow adjustment of the control deviation In the weather dependent control...

Page 18: ...point and end point of the curve can be set Setting range Factory settings Base point 10 40 C 25 C End point 25 90 C 60 C Setting parameters for the heating system Heating type Flow return temperature...

Page 19: ...offset per degree from the room set temperature of 21 C Example At an outside temperature of 5 C a flow set temperature of e g 50 C will be calculated for the settings of base point and end point in o...

Page 20: ...The flow temperature is increased by 6 K The higher the selected room influence the greater the influ ence of the room temperature on the flow temperature Connection of an OpenTherm Control Box with...

Page 21: ...l temperature sensor will be switched off external temperature sensor IP 65 9070459 Presence detector Temperature selection This temperature is used for control if the HVAC output of the presence dete...

Page 22: ...ure difference between actual tem perature and desired set temperature Example At 06 00 a m in the morning a change in the bathroom is programmed from reduction 17 C to comfort temperature 23 C Withou...

Page 23: ...ditions 5 Setting the error format Error notifications from OpenTherm heaters can be received depending on the manufacturer in a hexadecimal or decimal format see instructions for the OpenTherm heater...

Page 24: ...can be used to assign a new PIN The factory setting for the PIN is 0 New PIN can be entered 1 6 digits In case of Delete pairing 2nd pairing the PIN is set to 0 If the PIN is 0 the PIN will not be re...

Page 25: ...20 in accordance with EN 60529 Protection class III in accordance with EN 60730 1 Operating temperature 0 C 50 C Power reserve 4 hours Mode of operation Type 1 STU in accordance with EN 60730 1 Rated...

Reviews: