background image

22

ENGLISH

Note:

Checking, clearing or cancelling a holiday program is described

in section 4.8 on page 20.

5.2

Changing the Settings for Target
Temperatures

For the temperature profiles of the individual programs, you can
choose between three temperature values: Comfort, lower and anti-
freeze temperature.

These temperature values are programmed ex works. You can
change these according to your wishes.

5.3

Program P3

5.3.1

Overview "Program" menu

5. The holiday program is now programmed and is activated at the

set start time.

6. Reset the rotary switch to the desired program and close the

hinged cover.

7. While the holiday program is active, the display shows the target

temperature and the text line

Holiday

.

1. Open the hinged cover and turn the rotary switch to the MENU

setting.

2. With the buttons

or

, select the entry

Target temp

. Confirm

with the

OK

button.

3. The display first shows the comfort temperature.

With the buttons

or

, change the comfort, lower and anti-

freeze temperature one after the other. Confirm each setting with
the

OK

button. The display changes automatically.

4. After having set the antifreeze temperature, the setting of the tar-

get temperatures is completed. The display shows

End

and auto-

matically changes back after 3 seconds.

5. Turn the rotary switch to the desired program and close the

hinged cover.

MENU

TARGET TEMP

Service

Holiday

PROGRAM

Clock/Date

OK

New

Check

Clear

End

see 5.3.2
see 5.3.3
see 5.3.4

5. The holiday program is now programmed and is activated at the

set start time.

6. Reset the rotary switch to the desired program and close the

hinged cover.

7. While the holiday program is active, the display shows the target

temperature and the text line 

Note: 

Checking, clearing or cancelling a holiday program is 

described in section 4.8 on page 20.

5.2

Changing the Settings for Target
Temperatures

For the temperature profiles of the individual programs, you can 
choose between three temperature values: Comfort, lower and 
antifreeze temperature.

These temperature values are programmed ex works. You can 
change these according to your wishes.

1. Open the hinged cover and turn the rotary switch to the MENU

setting.

2. With the buttons 

or 

, select the entry                     Confirm

with the 

OK 

button.

3. The display first shows the comfort temperature.

With the buttons 

or 

, change the comfort, lower and anti-

freeze temperature one after the other. Confirm each setting with 
the 

OK 

button. The display changes automatically.

4. After having set the antifreeze temperature, the setting of the tar-

get temperatures is completed. The display shows        and auto-
matically changes back after 3 seconds.

5. Turn the rotary switch to the desired program and close the

hinged cover.

5.3

Program P3

5.3.1

Overview “Program” menu

Holiday

.

Target temp

.

End

see 5.3.2
see 5.3.3
see 5.3.4

Summary of Contents for 811 9 032

Page 1: ...ploi 29 Thermostat horloge Instrucciones de servicio 43 Cronotermostato Istruzioni per l uso 57 Cronotermostato Gebruiksaanwijzing 71 Klokthermostaat RAM 701 RAM 722 RAM 784 RAM 797 HF HF REC 4 RAM 36...

Page 2: ...ons are to be observed Interferences and changes to the device will lead to can cellation of the warranty Table of Contents 1 Designated Use 15 2 Safety Instructions 15 3 Description and Mounting 16 3...

Page 3: ...active Display for batteries to be replaced only RAMSES 811 top Display of the switch phases RESET button 3 Description and Mounting 3 1 Device Overview Hinged cover Display of the day of week 1 Monda...

Page 4: ...pump or storage hot air heating Control of a motor mixing valve Control via the circulation pump or storage hot air heating 3 2 Mounting and Electrical Connection Connection terminals mains 230 V Only...

Page 5: ...the OK button Set the minutes and confirm with the OK button Deutsch English Francais Italiano Espanol NL OK Hour 0 00 OK Hour 15 00 OK Minute 15 34 4 Installation and Operation For installation of RA...

Page 6: ...ogram only visible with opened hinged cover The fixed programmed temperature profiles and switch times are described in section 4 5 3 The display changes automatically to the date setting Set the year...

Page 7: ...1 or set the desired temperature profile automatic program at the rotary switch see section 4 5 on page 19 Set display type i e which information is shown in the display also see page 25 3 The check i...

Page 8: ...you want the comfort the lower or the antifreeze temperature for the set period Confirm with the OK button 4 9 Party Eco Program With the Party Eco function you can cancel the temperature profile of t...

Page 9: ...red program and close the hinged cover MENU TARGET TEMP Service Holiday PROGRAM Clock Date OK New Check Clear End see 5 3 2 see 5 3 3 see 5 3 4 5 The holiday program is now programmed and is activated...

Page 10: ...es of the next day are dis played etc CHECK 7 6 5 4 3 2 1 PROG 6 00 0 3 6 9 12 15 18 21 24h 21 0 C END 3 sec Empty no program stored in memory back to Program see 5 3 1 OK OK back to Program see 5 3 1...

Page 11: ...e switch times 2 Clearing the desired switch times Clear All Empty no program stored in memory Confirm In order to cancel the clearing process press the ESC button back to Program see 5 3 1 OK OK OK b...

Page 12: ...N N T N N Actual temp N N T N N Program name T T T T T Table Overview of the information shown in the display for different display types 7 6 5 4 3 2 1 PROG 6 00 0 3 6 9 12 15 18 21 24h 21 0 C T text...

Page 13: ...with OK Cancel with ESC OK OK back to see 5 4 1 5 30 0 1 C 0 2 C Set with buttons or 0 2 C 5 0 C back to or autom after 6 sec see 5 4 1 5 4 3 Selecting the language Select the language with the butto...

Page 14: ...me Month Weekend within month Hour for changeover e g from 2 a m to 3 a m Start of winter time Month Weekend within month OK Note Time for changeover to winter time is taken from summer time e g back...

Page 15: ...eries 2 x alkaline batteries 1 5 V type AA Power reserve during battery replacement 10 minutes 6 Maintenance and Repair With the exception of a regular replacement of the batteries for the RAMSES 811...

Page 16: ...n AG Hohenbergstr 32 72401 Haigerloch Tel 49 0 74 74 6 92 0 Fax 49 0 74 74 6 92 150 Service Tel 49 0 90 01 84 32 36 Fax 49 0 74 74 6 92 207 hotline theben de Adresses telephone numbers etc at www theb...

Reviews: