4.3 Lighting Settings (recommended)
Brightness value
Setting the desired brightness (Lux)
scale
●
Transfer zones (non-working area)
approx. 2
●
Bright transer zones
approx. 3
●
Deactivation of brightness measurement
«on»
Depending on the installation location, natural light intensity, furniture, re-
flection characteristics of the room and the furniture, an adjustment of the
setting by 1 or 2 steps may be necessary.
If setting values for brightness <= 2.5
and
switch-off delay time light <= 2 min:
faster response to changes in actual brightness when in operating mode
switching of one lighting row.
Brightness difference
(Outlets Lights A, B active)
A detector can switch or control up to two lighting rows. The lighting row
nearest the window (know as Output A) usually requires less light.
●
homogenous light relationship
+20%
●
large brightness differences
+40%
Switch-off delay time
For settings between 2–15 min the switch-off delay time has a self-learning
feature which varies within this range. Settings <2 min or >15 min remain
constant.
●
Transfer zones
approx. 5 min