technical data
7
TSL.960
MANUAL
FRONT
SIDE
Technical Data: Electrical
Power Supply (Battery)
6V CR-P2 Lithium Battery
Power Supply (Mains)
100-240V; 1.5A; 50-60Hz PSU.
Output (Max)
6V; 6W max
Power Consumption
< 80μA
Solenoid Valve
6V
Water Ingress (PSU)
IP67
Cable Lengths
Connection to sensor cable - 400mm
Connection to fused supply - 1.5m
Technical Data Sensor
Sensor Type
Infra red
Pre-set Sensor Range
120mm
Maximum Sensor Range
250mm
Comfort Delay
2 seconds
Security Time-out
30 seconds
Operating Temperature
0 to 50ºC
Response Time (max)
< 300ms
Compliance
WRAS
Pending
CE
PSU conforms to RoHS, REACH, EN15091
BREEAM
Qualities for up to 5 credits as part of water