background image

 

 

- 9 - 

40K Cavitation Operate Interface   

 

                                                              9 

1                                                            10                                   

2                                                            11 

3                                                            12 

                                                              13 

       

             

5          6            7            8 

     

1. 

Time adjustment

 

Enter into 40K Cavitation function interface, 
the system default working time is 30   
minutes, the operator may click (Button 1) ,   
re-use (Button 12) & (Button 13) to regulate   
time by need, time in minutes.   

2. Power 

adjustment

 

Power system default is "1", the operator   
firstly press (Button 2). Power display cursor   
will appear at this time, then use the   
(Button 12) & (Button    13) to adjust the   
appropriate  power,  power  adjustment  range  is  0-10  levels,  generally 
recommended  that  the  shallow  fatty  part  with  4-6  levels,  deep  fat  parts 
with 8-10 levels.   

3. Mode 

adjustment 

The  default  mode  is  "Discontinuity-wave  mode",  the  operator  click 
(Button 3) by need. This mode displays cursor will appear, and then use 
(Button12)  &  (Button  13)  to  adjust  the  appropriate  mode.  40K  mode  is 
divided  into  pulse  wave  (

)  and  continuous  wave  (

),  shallow  fat 

part is generally recommended to use continuous wave, deep fat part use 
discontinuity wave. 
Operator  set  parameters  related  functions,  can  click  the  Start  button 
(Button  6),  when  the  instrument  starts  working,  time  is  countdown,  and 
working  probe  produces  Acoustic  vibration.  According  to  need  in 
operation required by the adjustment method adjust the power, mode and 

40K 

Cavitation 

Probe 

Operate Interface 

1. Time selection 

2. Power selection 

3. Mode selection 

4. Function switch

Left

 

5. Return to main interface 

6. Start/Stop   

7. Return to previous menu 

8. Function switch

Right

 

9. Time display 

10. Power display 

11. Mode display 

12.Time/Power/Mode increase 

13.Time/Power/Mode decrease 

Summary of Contents for SE-C83

Page 1: ...Evolutionary solution for fat reduction Professional Beauty Equipment SE C83 User Manual Http www SPAelf com...

Page 2: ...invasive Cavitation technology in 2010 which means do on any part of the body for rapid fat soluble by the in vitro ultrasound equipment and body location precision that can dissolve fat thickness to...

Page 3: ...ion phenomenon in the liquid This phenomenon is generated by the momentary pressure Cavitation Technology Cavitation is defined as under the frequency the energy of the sound waves produce many gaps i...

Page 4: ...cantly improved wrinkles sagging eyelids raise up eyes bigger slack jaw has also become tight and shaping the whole body are completely new Find young beautiful face like a decade ago really is not a...

Page 5: ...a relatively low power can be obtained sufficient energy together with the special design of the safety button the entire treatment doubly safe Q Q Q Q What kind of people suitable for 5M Multipolar R...

Page 6: ...eping longer Because a lot of skin problems lies in prevention Cold Laser Weight Loss Techniques By 640nm high energy narrow spectrum red light resulting in a unique photochemical reactions cells quic...

Page 7: ...emoval tighten skin easily Instrument installation instructions 1 2 3 4 5 6 8 7 9 1 Seven polar RF probe 2 40K cavitation probe 3 Tri polar RF probe 4 Touch screen 5 Seven polar RF interface 6 40K cav...

Page 8: ...rted 2 Enter into the host interface the user can use the icon to select the corresponding function 3 Click on the icon interface displays the working probe this time there will be corresponding to th...

Page 9: ...operator click Button 3 by need This mode displays cursor will appear and then use Button12 Button 13 to adjust the appropriate mode 40K mode is divided into pulse wave and continuous wave shallow fa...

Page 10: ...or will appear at this time then use the Button 10 Button 11 to adjust the appropriate power power adjustment range is 0 10 levels generally recommended that the hand and feet part with 3 6 levels abd...

Page 11: ...ton 10 Button 11 to adjust the appropriate power power adjustment range is 0 10 levels generally recommended that the hand and feet part with 3 6 levels abdomen back buttocks parts with 8 10 levels Op...

Page 12: ...system and compatible with different 40K generator the user need only a continuous click the touch screen Lower right and upper left corneron the boot screen can be adjusted the 40K best output freque...

Page 13: ...ith treatment Treatment settings 12 times treatment the former 5 times day once After 7 times do once every 3 days Except during menstruation Warm prompt Abdominal weight loss proper operation time sh...

Page 14: ...ries can be targeted acts on the site of fat accumulation when operation thymus sides and underarms in passing the intensity should not be too large Acting on the back on the zoom position the accessa...

Page 15: ...rated in the hips the best choice to choose the chair with backrest Correct wearing underwear Underwear especially thin triangles can t tightly wrap hip easy to make buttocks sagging and deformation r...

Page 16: ...ed fixed point one hand grasp the arm slid the accessory along the same route to its original position 2 Pushing by above diagonally from one end of the arm and back pushing back at the starting point...

Page 17: ...or subject to the instrument training 2 To avoid thyroid bone lymph when perations 3 Avoid wounds sensitive parts 4 Instrument when not in use turn off the instrument in order to avoid excessive work...

Reviews: