background image

Glazing Plan for Silverline lean-to glazed with large pane 

TOUGHENED glass. 

Use this plan, not the one in your manual.  

Code 

Size (mm) 

8x6 

10x6 

12x6 

610 x 610 

610 x 457 

610 x 525 

E As 

drawing  1 

G  

As drawing 

H As 

drawing  1 

610 x 610 2mm plastic 

Curved Glass 610 x 535 

610 x 1660 

P As 

drawing  1 

610 x 995 

BB 

610 x 1345 

10 

11 

HH 

610 x 764 

JJ 

610 x 916 

 

TOTAL 

29 

33 

36 

288 

200 

610 

482 

283 

195 

610 

91 

389 

610 

49 

535 

BB BB  BB 

BB 

BB 

BB 

BB 

BB 

JJ 

HH 

Pictured above 2’ long black 
plastic Muntins. Use these 
strips where indicated on the 
diagrams to join together panes 
of glass.  The Muntins are 
indicated with a;   

FOR LOUVRE WINDOW 
REPLACE 

1 x BB (610 x 1347) 

WITH  

1 x A (610 x 700)  

 

 

+ 1 x 610 x 200  

 

 

+ 5 x 573 x 100 (Louvre glass) 

IMPORTANT:  A Louvre MUST go  
in-between the two make-up panes.

 

Summary of Contents for Silverline

Page 1: ...spinner see picture it is much quicker and easier to use than a 10mm spanner also pictured You may have an attachment in a ratchet set that will suit this job Other tools that may be may be required are shown in the picture to the right Using the manufacturers manual Read the information relevant to each stage of construction immediately before you begin Study each drawing carefully before you beg...

Page 2: ...glazing strips must be used to fit toughened glass in the ends not the grey strips 452 which are redundant The louvre can be located in either the back or the side Siliconing Tips Before glazing it is a good idea to silicone behind each corner plate 205 It is also advisable to create a silicone runway where the curved bars make contact with the gutter This helps any water which lands on the roof t...

Page 3: ...nt sides and top to be pushed on much easier Fit roof vent bottom bar centrally over the glass and carefully knock down into position Fix top bar over glass attach with screws through the holes in the left and right vent sides Check diagonal measurements are equal for squareness Adjust if necessary and tighten all screws Push the rubber back under the groove with a flat wooden edge to tidy up the ...

Page 4: ...position 986 Door track Part 758 is shown in the manual the wrong way round because of the door end bracings It can only fit on one way and that is opposite to the S diagram page 15 the manufacturer has shown The Pictures far left show the bar the correct way up It is a good idea to use WD40 in your door track and door track sill to make the door glide easily The door needs to be slid onto the doo...

Page 5: ...ng 1 1 1 R 610 x 995 1 2 2 BB 610 x 1345 9 10 11 HH 610 x 764 1 1 1 JJ 610 x 916 1 1 1 TOTAL 29 33 36 P H 288 200 610 6 482 283 195 610 91 389 E G 610 49 535 J BB BB BB C C G H J BB BB BB BB BB D JJ HH E K K K L R A L J Pictured above 2 long black plastic Muntins Use these strips where indicated on the diagrams to join together panes of glass The Muntins are indicated with a FOR LOUVRE WINDOW REPL...

Page 6: ...re than 30mm width should be made to fit the aluminium section as shown in fig 2a When the greenhouse has been assembled it can be screwed to the base with no 12 screws and rawlbolts not supplied through the sill bar not pre drilled in fig 2a IMPORTANT If you wish to erect your greenhouse on a solid concrete plinth you should follow the outside dimensions in fig 3 However it is important to avoid ...

Reviews: