Page 6
1. Make sure that the trigger is locked.
2. Place fogger on a level surface when lighting and preheating.
3. Strike match and place under coil visible through shroud. (Fig. 3)
4. Open fuel valve a maximum of 1/4 turn. Ignition will take place immediately.
5. Should the gas blow the match out, turn gas off and wait 30 seconds before attempting to
re-ignite.
6. If burner will not light, make sure propane gas cylinder is not empty, is screwed in securely,
and not cross threaded (no tank threads should be visible). Do not permit gas to escape
without prompt ignition.
7. Allow the fogger to pre-heat for 1-2 minutes. While pre-heating some fl ame may appear
around shroud. This is normal and should not be a cause for concern.
Always
preheat your
fogger for one to two minutes, while keeping the fogger level with the ground.
Failure to
preheat the burner may cause an uncontrolled fl ame in the fogger burner, should the
fogger be pointed toward the ground. Failure to preheat the burner may also clog the
burner orifi ce, damaging your fogger.
8. Release the trigger lock and the fogger is ready to operate.
OPERATING INSTRUCTIONS