background image

Instruction Manual

& Safety Warnings

IMPORTANT:    Even  if  you  have  the  Basement  Watchdog  Special
Backup Sump Pump System installed by someone else, you must read
and follow the safety information contained in this manual.  Failure
to do so could result in property damage, serious injury, or death.

Battery Backup

Sump Pump

System

Table of Contents

Important Safety Warnings and
Instructions

Electrical Precautions

1

Battery Preparation

1

Battery Precautions

1

Introduction

Items Included in System

2

Additional Items Needed

2

System Specifications

2

Replacement Parts List

2

Pump & Pipe 
Installation Instructions

Installation Options

3

Direct Discharge to Outside

4

Connection to Existing Discharge

5

Direct Discharge for Narrow Sumps

6

Connection to Existing Discharge for 
Narrow Sumps

7

Battery Instructions

Preparation of the Battery

8,9

Control Unit Connections

Positioning the Float Switch

9

Connecting the Pump

9

Installing the Battery Fluid Sensor 10
Connecting the Battery

10

Connecting the Charger

10

Understanding the Warning
Lights and Alarms

Silencing the Alarm
During an Emergency

11

Battery Alarm

11

Cleaning Battery Terminals

11,12

Replacing the Battery

12

Fuse Alarm

13

Water Alarm

13

Pump Alarm

14

Replacing the Pump

14

Power Alarm

15

Charging

15

System Operating

15

Testing the System

Test-Reset-Silence Button

15

Testing the Float Switch

15

Using the Remote Notification

Remote Terminal

15

Remote Alarm

15

USB Data Port

16

Connect Modules

16

Maintenance Check List

16

Parts & Service Information

Technical Support

16

Troubleshooting Guide

17

Warranty

18

Other Products

19

This manual is for the systems that
have the BWSP-A backup controller,
which can accommodate maintenance
or maintenance free batteries.

Summary of Contents for Special CONNECT

Page 1: ...ge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 9 Control Unit Connections Positioning the Float Switch 9 Connecting the Pump 9 Installing the Battery Fluid Sensor 10 Connectin...

Page 2: ...observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in...

Page 3: ...mps or a Y connector and two 2 check valves depending on the installation method you use A surge protector recommended Six 6 quarts of 1 265 specific gravity battery acid 30HDC140S and BW 30F Battery...

Page 4: ...ove the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so that the backup pump and the main pump do not touch each other Select the installation...

Page 5: ...he discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so tha...

Page 6: ...ed at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 P...

Page 7: ...e path of the rest of the pipe and the details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns Mo...

Page 8: ...he Basement Watchdog pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe abov...

Page 9: ...IS PAGE IF THE TOP OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE 9 FOLLOW THE INSTRUCTIONS ON PAGE 9 Contains sulfuric acid Wear eye and clothing protection If battery acid contacts skin or clothing wash...

Page 10: ...uously The system will NOT warn you if the fluid level is low in this configuration You will need to check your battery every couple of months to see if it needs water If the battery dries out the sys...

Page 11: ...see if it needs water If the battery dries out the system will not work If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE...

Page 12: ...the battery should recharge If no other lights are on this means the terminals may be corroded and the battery cannot charge properly Unplug the charger from the wall outlet Then check the battery ca...

Page 13: ...he wall outlet You should provide additional protection for the control unit by using a surge protector 10 If any of the alarms are sounding press the YELLOW button on the front of the control panel f...

Page 14: ...disconnect the battery cables from the battery Then call Glentronics technical support for instructions at 800 991 0466 option 3 You may need to replace the pump 4 Plug the main AC pump back into the...

Page 15: ...ing up 3 Fan the area around the top of the battery with a piece of cardboard or another non metallic material to remove any hydrogen or oxygen gas that may have been emitted from the battery 4 Remove...

Page 16: ...be taken to prevent a flood To silence certain alarms for 24 hours press the YELLOW button for 5 seconds until you hear a buzz The alarms will automatically re activate in 24 hours TESTING THE FLOAT S...

Page 17: ...sit www BasementWatchdog com MAINTENANCE CHECK LIST Maintenance should be performed 1 2 times per year 1 Lift the float switch as described at left 2 Remove all debris from the bottom of the pit and p...

Page 18: ...ower cord is plugged in securely None if the utility company has instigated brown outs Otherwise reduce the number of other appliances on the circuit Make sure the pump is securely plugged into the ba...

Page 19: ...ed below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of da...

Page 20: ...e cage Should one float fail to operate the second float automatically activates the pump The protective cage prevents debris or other wires from interfering with the movement of the float It can be u...

Reviews: