Battery needs replacing
During the alarm, it slowly
lights up green and slowly goes
out
Replacement of the detector battery is
described in the Battery Replacement
paragraph
Performance testing
The Ajax security system allows conducting tests for checking the functionality of connected
devices.
The tests do not start straight away but within a period of 36 seconds when using the standard
settings. The test time start depends on the settings of the detector scanning period (the
paragraph on “Jeweller” settings in Hub settings).
Installing the device
Selecting an installation location
Location of the DoorProtect detector determines its remoteness from the Hub and the presence
of any obstacles between the devices hindering the radio signal transmission: walls, inserted
floors, large-size objects located within the room.
Check the signal level at the installation location.
If the signal level is one division, we cannot guarantee stable operation of the security system.
Take possible measures to improve the quality of the signal! As a minimum, move the device -
even 20 cm shift can significantly improve the quality of reception.
If, after moving, the device still has a low or unstable signal strength, use a radio signal range
extender ReX.
The detector is located either inside or outside the door case (window frame).
When installing the detector in the perpendicular planes (inside the case/frame), use the small
magnet from the set. The distance between the magnet and detector should not exceed 1 cm.
When positioning the parts of DoorProtect in the same plane, use the big magnet. Its actuation
threshold - 2 cm.
The magnet is attached to the moving part of the door (window) to the right of the detector. If
necessary, the detector may be overturned or positioned horizontally.