Slug Release
Definition
The slug line is turned on. All Logic Assemblies that are connected in one
continuous string will release at the same time regardless of zone status.
Configuration When using TB2; JP1, 1-2 and JP2, 1-2 to release all Logic Assemblies.
User Action
Apply a high (24VDC/115VAC) signal to TB2, 1-2 if using isolated inputs.
Pulse Release
Definition
Upstream Logic Assembly releases for a length of time set by the ZS ON
potentiometer (0-20s) and then accumulates for length of time set by the ZS OFF
potentiometer (0-20s).
Configuration When using TB1; JP3, NC to oscillate the release of the upstream Logic
Assembly.
Adjust ZS ON and ZS OFF potentiometers from 0 to 20 seconds.
User Action
Apply a high (24VDC/115VAC) signal to TB1, 1-2 if using isolated inputs.
Logic Interrupt
Definition
Upstream logic line is turned off. The upstream Logic Assembly is forced to
accumulate when it detects a package regardless of the downstream zone
status.
Configuration
When using TB1; JP3, 2-3 to accumulate the upstream Logic Assembly.
When using TB4; JP4, 2-3 to accumulate the upstream Logic Assembly.
User Action
Apply a high (24VDC/115VAC) signal to TB1, 1-2 if using isolated inputs.
Or
Apply a high (24VDC) signal to TB4, 3 if using a non-isolated input.
Zone Delay
Definition
Delays turning on the upstream logic line. After the downstream zone clears, the
upstream Logic Assembly releases, but only after a length of time set by LOGIC
potentiometer (0-20s).
Configuration
Adjust LOGIC potentiometer from 0 to 20 seconds.
User Action
No action required.