P/N: 1176718
REV: 02/17/2021
Page
11
of
32
Chapter 5: F
EATURES
5.1: A
LL
I
NTELLI
ROL
P
OWER
S
UPPLIES
Lockable Disconnect Switch
All IntelliROL power supplies include a lockable disconnect switch. This allows for lockout/tagout at the
power supply.
IntelliROL Power Supply Lockable Disconnect Switch
Internal Branch Circuit Protection
IntelliROL power supplies are available with internal branch circuit protection. If proper branch
circuit protection is not available upstream of the IntelliROL power supply, the power supply
should be purchased with branch circuit protection built in.
Output Current Boost
Each IntelliROL power supply can provide a boost in output current over its nominal rating. The
extra current is available for a short period of time. Since IntelliROL conveyor draws maximum
current at startup, this current boost is a definite advantage.