![TG Electronics HSY-S212W User Manual Download Page 3](http://html.mh-extra.com/html/tg-electronics/hsy-s212w/hsy-s212w_user-manual_1099062003.webp)
Press
1 Eight card number # , Eight card number # , … #
Automatically increase, the user ID automatically generated by this machine,
the range
is 1 ~ 2000,
and search from small to large.
4.2.3
Designated ID No swipe card increase:
Press 1 ID Number # Reading card
,
ID Number # Reading
card , … #
4.2.4 Designated ID No and card No increase:
Press 1 ID Number # Eight card number # , ID Number # Eight card
number # , … #
Note: input ID digits for 1-4 digits, The range is 1 ~ 2000, such as 1,01,001,0001 ID
number all expressed 1.
Add card user will automatically generate a default password "1234", but this password
can't open the door,
only for a user to change a new password.
4.2.5 Designated ID No and password increase:
Press 1 ID No # password # ID No # Password # … #
Note: applicable to no card users, password and card unrelated, input digits for four,
but not for "1234"
4.3 Delete user
4.3.1 Delete swipe card
Press 2 Reading card Reading card … #
4.3.2 Delete Designated card Number
:
Press
2 Eight card number #
,
Eight card number #
,
… #
4.3.3 Delete Designated ID Number
:
Press 2 ID No # ID No # … #
4.3.4
Delete all
:
Press 20000 #
4.4
Door open method setting
:
4.4.1
Card open
:
Press 3 0 #
4.4.2
Card + Password open
:
Press 3 1 #
4.4.3
Card or Password open
:(
Factory default
)
Press 3 2 #
4.5
Unlock time setting
:
Press 4 0
~
99 #
Note: The lock time range "0 to 99 seconds ", the factory default is 5 seconds
4.6 Alarm time setting
:
Press 5 0
~
3 #
Note: The alarm time range "0 to 3 minutes ", the factory default is 1 minute
4.7 Magnetic Alarm Function setting
: