background image

 

   

 

                                          Figure 3 Access Control Power Supply Cabling diagram 
 

9 Packing list 

 

Name 

Model/specification 

Quantity

Note 

Metal waterproof 

access control 

HSY-S212W access 

control 

1  

User manual 

HSY-S212W access 

control 

1  

Tapping screws 

Φ

4mm×28 mm 

Used for installation fixed 

Stopper 

Φ

6mm×30 mm 

Used for installation fixed 

Star screwdriver 

Φ

20mm×60mm 

1 Secial 

Star screws 

Φ

3mm×6mm 

1 Used

 

between the front 

cover and back cover for a 

fixed 

 

 

Warm Tip: 

* Please don't secretly repair machine, if any problem, please return to factory 
maintenance. 
* Before the installation on the wall, if you want to punch, please check carefully wiring or 
line tube, prevent drilling broken wiring etc unnecessary trouble, please use safe glasses 
when drilling or fixed line clip. 
* If product upgrades, specifications will likely differ, without prior notice. 
 

Summary of Contents for HSY-S212W

Page 1: ...ade microprocessors Strong anti interference ability Safety and reliability is extremely high can provide a powerful security for 2 000 users It has strong functions such as low power consumption Luminous keyboard independent passwords wiegand26 output the output short circuit protection door magnetic alarm prevent demolition alarm exit button the doorbell interface level of security Settings etc ...

Page 2: ...C9 28V Static Current 30mA Reading Range 3 8cm Capacity 2000 users Ambient Temperature 25 60 Degree Ambient Humidity 10 90 Electricity lock output 3A Alarm output 20A Output short circuit protection time 100μS Open time 0 99 seconds adjustable Size 120 56 18mm 4 Administrator operation Restore factory settings Disconnect the power of the mechine press key at the same time conntect the power for it...

Page 3: ...ord 4 2 5 Designated ID No and password increase Press 1 ID No password ID No Password Note applicable to no card users password and card unrelated input digits for four but not for 1234 4 3 Delete user 4 3 1 Delete swipe card Press 2 Reading card Reading card 4 3 2 Delete Designated card Number Press 2 Eight card number Eight card number 4 3 3 Delete Designated ID Number Press 2 ID No ID No 4 3 4...

Page 4: ... time 5 User operations 5 1 User use card modify password Press Reading card Old password New password Repeat the new password 5 2 User use ID No modify password Press ID No Old password New password Repeat the new password Note applicable to a card or without card users if the user password is 1234 must use card to modify 5 3 Card open Reading card Effective namely open 5 4 Password open Press Us...

Page 5: ...hod 8 1 1 On the wall of the aperture size machine on the pan is playing well with a hole or installed 2 exisiting junction box plus connecting Figure 1 Figure1 8 1 2 Put the lead wire from Bottom shell of the outlet hole oout he connection of cable needed Unused lines wrapped with insulating tape isolated to prevent short circuit 8 1 3 Finish line Install the front cover to the back cover Finally...

Page 6: ... GND 7 D_IN Brown Magnetic switch one end magnetic switch another end connected GND 8 DC 12V Red Power supply 9 28V input DC input 9 GND Black GND 10 NO Blue Relay normally on end Connected positive electric lock 11 COM Purple Relay Public end Connected GND 12 NC Orange Relay Closed end connected negative electric lock 8 3 Cabling diagram 8 3 1 Ordinary power supply Cabling diagram Figure 2 Ordina...

Page 7: ...fixed Star screwdriver Φ20mm 60mm 1 Secial Star screws Φ3mm 6mm 1 Used between the front cover and back cover for a fixed Warm Tip Please don t secretly repair machine if any problem please return to factory maintenance Before the installation on the wall if you want to punch please check carefully wiring or line tube prevent drilling broken wiring etc unnecessary trouble please use safe glasses w...