7.0  WARRANTY

Task Force Tips LLC, 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA (“TFT”) warrants to  the original purchaser of its 
Twister and Bubble Cup  series nozzles (“equipment”), and to anyone to whom it is transferred, that the equipment shall be free from 
defects in material and workmanship during the fi ve (5) year period from the date of purchase.
TFT’s obligation under this warranty is specifi cally limited to replacing or repairing the equipment (or its parts) which are shown by 
TFT’s examination to be in a defective condition attributable to TFT. To qualify for this limited warranty, the claimant must return the 
equipment to TFT, at 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA, within a reasonable time after discovery of the 
defect. TFT will examine the equipment.  If TFT determines that there is a defect attributable to it, TFT will correct the problem within 
a reasonable time.  If the equipment is covered by this limited warranty, TFT will assume the expenses of repair.
If any defect attributable to TFT under this limited warranty cannot be reasonably cured by repair or replacement, TFT may elect to 
refund the purchase price of the equipment, less reasonable depreciation, in complete discharge of its obligations under this limited 
warranty. If TFT makes this election, claimant shall return the equipment to TFT free and clear of any liens and encumbrances.
This is a limited warranty. The original purchaser of the equipment, any person to whom it is transferred, and any person who is 
an intended or unintended benefi ciary of the equipment, shall not be entitled to recover from TFT any consequential or incidental 
damages  for  injury  to  person  and/or  property  resulting  from  any  defective  equipment  manufactured  or  assembled  by TFT.  It  is 
agreed and understood that the price stated for the equipment is in part consideration for limiting TFT’s liability. Some states do not 
allow the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
TFT shall have no obligation under this limited warranty if the equipment is, or has been, misused or neglected (including failure to 
provide reasonable maintenance) or if there have been accidents to the equipment or if it has been repaired or altered by someone 
else.
THIS  IS  A  LIMITED  EXPRESS  WARRANTY  ONLY.  TFT  EXPRESSLY  DISCLAIMS  WITH  RESPECT  TO  THE  EQUIPMENT 
ALL  IMPLIED  WARRANTIES  OF  MERCHANTABILITY AND ALL  IMPLIED  WARRANTIES  OF  FITNESS  FOR A  PARTICULAR 
PURPOSE. THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THIS DOCUMENT.
This limited warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.

8.0  ANSWERS TO YOUR QUESTIONS

We  appreciate  the  opportunity  of  serving  you  and  making  your  job  easier.  If  you  have  any  problems  or  questions,  our  toll-free 
“Hydraulics Hotline”, 219-548-1033, is normally available to you 24 hours a day, 7 days a week.

9.0  MAINTENANCE

TFT nozzles are designed and manufactured to be damage resistant and require minimal maintenance. However, as the primary 
fi refi ghting tool upon which your life depends, it should be treated accordingly. Do not drop or throw equipment.

9.1  LUBRICATION

All Task Force Tip nozzles are factory lubricated with high quality silicone grease. This lubricant has excellent washout resistance 
and long term performance. If your department has unusually hard or sandy water, the moving parts may be aff ected. Foam agents 
and water additives contain soaps and chemicals that may break down the factory lubrication. 
The moving parts of the nozzle should be checked on a regular basis for smooth and free operation, and signs of damage. IF THE 
NOZZLE  IS  OPERATING  CORRECTLY,  THEN  NO ADDITIONAL  LUBRICATION  IS  NEEDED. Any  nozzle  that  is  not  operating 
correctly should be immediately removed from service. 

9.2 SERVICE TESTING

In accordance with NFPA 1962 (2013), nozzles must be tested a minimum of annually. Nozzles failing any part of this test must be 
removed from service, repaired and retested upon completion of the repair.

9.2.1  HYDROSTATIC TESTING

Each nozzle with a shut off  mechanism shall be tested in the following manner.

1. The nozzle shall be placed in a device capable of holding it and the shut off  shall be closed.
2. A device capable of exerting a hydrostatic pressure of 300 psi (2070 kPa) or 1.5 times the maximum operating pressure, 
whichever is higher, shall be attached to the nozzle.
3. All air shall be bled from the system.
4. The gage pressure shall be increased by 50 psi (3.5 bar or 345 kPa) increments, held for 30 seconds at each pressure up to 
the maximum pressure for which the nozzle is being tested, and then held for one minute without leakage.
5. There shall be no sign of leakage through the valve or shut off .

Summary of Contents for Ultimatic ER

Page 1: ...n who has not read and understood all operating and safety instructions is not qualified to operate the Ultimatic ER Nozzle Call 800 348 2686 with any questions This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the nozzle This manual should be kept available to all operating and maintenance pers...

Page 2: ...UESTIONS 10 9 0 MAINTENANCE 10 9 1 LUBRICATION 10 9 2 SERVICE TESTING 10 9 2 1 HYDROSTATIC TESTING 10 9 2 2 FLOW TESTING 11 9 2 3 RECORDS 11 9 3 REPAIR 11 10 0 INSPECTION CHECKLIST 12 Copyright Task Force Tips LLC 2008 2019 LIY 500 April 8 2019 Rev14 MANUAL Remote Control RC Monitor Electrical Controls Supplemental Instructions for use with RC Monitor Manual INSTRUCTIONS FOR INSTALLATION SAFE OPER...

Page 3: ...k to the nozzle will depend on the following factors Voltage of the line or equipment Distance from the nozzle to the line or equipment Size of the stream Whether the stream is solid or broken Purity of the water1 1 The Fire Fighter and Electrical Equipment The University of Michigan Extension Service Fourth Printing 1983 Page 47 CAUTION Fire streams are capable of injury and damage Do not direct ...

Page 4: ...efore use Obtain safety information at www tft com serial number WARNING PRODUCT LABEL Figure 2 1 Models and Terms 2 2 MECHANICAL SPECIFICATIONS Weight 6 4 lbs 2 9 kg Hydrostatic burst pressure minimum 1200 psi 83 bar Operating temperature range of fluid 33 to 120º F 1 to 50º C Storage temperature range 40 to 150º F 40 to 65º C Actuation Force 173 lbs 78 5 kg Speed Stream Fog 3 4 sec 3 4 sec Materi...

Page 5: ...am at a rapid enough rate Removal of empty foam containers Keeping clear path to deliver foam as hoses other equipment and vehicles are deployed WARNING Improper use of foam can result in injury or damage to the environment Follow foam manufacturer s instructions and fire service training to avoid Using wrong type of foam on a fire i e Class A foam on a Class B fire Plunging foam into pools of burnin...

Page 6: ...10 25 50 75 GPM FLOW LPM FLOW 38 95 190 284 LBS REACTION 3 10 23 36 26 69 84 91 E 100 53 110 PSI INLET PRESSURE KGF REACTION 1 4 4 5 10 4 16 3 KGF CM 2 INLET PRESSURE 1 8 4 8 4 1 6 4 E 379 24 0 7 7 F 125 70 122 E 473 31 8 8 6 100 PSI ELECTRIC REMOTE CONTROL NOZZLE 60 50 40 40 30 20 20 10 0 0 80 100 120 140 A B C D E F These trajectories reach and reaction numbers are provided for reference All dat...

Page 7: ... CURVE 10 25 50 75 GPM FLOW LPM FLOW 38 95 190 284 LBS REACTION 3 13 31 49 27 90 135 151 E 100 68 165 PSI INLET PRESSURE KGF REACTION 1 4 5 9 14 0 22 2 KGF CM 2 INLET PRESSURE 1 9 6 3 9 5 10 6 E 379 30 9 11 6 F 125 87 175 F 473 39 5 12 3 150 PSI ELECTRIC REMOTE CONTROL NOZZLE 60 50 40 40 30 20 20 10 0 0 80 100 120 140 A B C D E F These trajectories reach and reaction numbers are provided for refer...

Page 8: ...uring flush the nozzle reaction decreases as the pattern becomes wider and the pressure drops The nozzle reaction increases when returning the nozzle from the flush position When used with a TFT RC Monitor equipped with Smart Stream technology the Fog button must be pressed and held a second time to reach the Flush position after having reached Full Fog The purpose of the Smart Stream feature is to ...

Page 9: ...I 1 B820 ER 100 BARREL SUB ASS 120 PSI 1 B820 ER 120 BARREL SUB ASS 150 PSI 1 B820 ER 150 12 BARREL LABEL BLUE 1 B740 BARREL LABEL RED 1 B740 RED INDEX DESCRIPTION QTY PART NUMBER 13 O RING 030 1 VO 030 14 VALVE PLUG 1 B590 15 O RING 109 1 VO 109 16 I O SCREW 1 B595 17 7 32 TORLON BALL 4 V2130 TORLON 18 ER SHAPER GUIDE 1 B514 19 NAME LABEL BLUE 75 PSI 1 B745F NAME LABEL RED 100 PSI 1 B745 NAME LAB...

Page 10: ...een repaired or altered by someone else THIS IS A LIMITED EXPRESS WARRANTY ONLY TFT EXPRESSLY DISCLAIMS WITH RESPECT TO THE EQUIPMENT ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND ALL IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE THERE IS NO WARRANTY OF ANY NATURE MADE BY TFT BEYOND THAT STATED IN THIS DOCUMENT This limited warranty gives you specific legal rights and you may also have oth...

Page 11: ...ire hose couplings nozzles and fire hose appliances 2013 ed Section 5 5 4 Quincy MA National Fire Protection Agency 9 3 REPAIR Factory service is available with repair time seldom exceeding one day in our facility Factory serviced nozzles are repaired by experienced technicians to original specifications fully wet tested and promptly returned Repair charges for non warranty items are minimal Any re...

Page 12: ...tion if applicable 9 There is no damage to the nozzle tip 10 The shut off valve if so equipped operates as designed and shuts the flow off completely BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 Shut off valve if so equipped closes off the flow completely 3 There are no broken or missing parts 4 There is no damage to the...

Reviews: