background image

 

 

 

29 

7.1 Installation of the cabinet on the wall 

The cabinet has four attachment points isolated from the interior. Marking of the 
attachment points is shown in Figure 7.3. The marking template is included with 
the packaging. 

 

 
Figure 7.3 

– Marking of attachment points 

 

IMPORTANT!

  Drilling  of  the  enclosure  will  lead  to  loss  of  the  switch  integrity 

and result in the loss of product warranty. 

 
 
 

7.2 Installation of the cabinet on lamp posts 

To  mount the  cabinet  on  the  poles,  use  TFortis-2  pole mounting kit for square 
and round supports. 
 

Summary of Contents for PSW-2G6F+UPS-Box

Page 1: ...Multifunction Gigabit Managed Switch with PoE PoE IEEE802 3af at support and integrated UPS for connecting six IP cameras PSW 2G6F UPS Box Operating Manual Version 1...

Page 2: ...W SFP port operates only at 1000 Mbps Fast Ethernet SFP modules will not operate To ensure proper operation of lightning protection provide proper grounding according to the Electrical Code use a shie...

Page 3: ...3 8 3 Cable tester 18 3 8 4 Remote camera polling 18 3 9 Built in UPS 18 3 9 1 Switching to battery power 19 3 9 2 Battery charging 20 3 9 3 Battery discharge 20 3 9 4 Cold start 22 3 9 5 Battery fun...

Page 4: ...ed for building IP video surveillance networks Figure 1 PSW 2G6F UPS Box connection scheme 2 Features The switch enclosure is made of reinforced polycarbonate and is absolutely corrosion resistant The...

Page 5: ...ted pair to power both the camera and the camera housing via PoE For safe and guaranteed start of video cameras in freezing weather TFortis TH equipment allows for preheating of camera housings The en...

Page 6: ...oot the camera automatically over PoE It allows to create unattended IP video surveillance networks Two gigabit ports allow to connect switches in a chain Support of STP RSTP protocols allows to creat...

Page 7: ...7 3 Description 3 1 Appearance Figure 3 1 1 PSW 2G6F UPS Box external appearance Figure 3 1 2 PSW 2G6F UPS Box interior...

Page 8: ...illed polycarbonate IK10 impact protection rating due to fiber glass reinforcement Dust and moisture protection rating IP66 Fire resistance UL94 5VA Electrical insulation 1500VDC UV resistance UL 746C...

Page 9: ...9 3 4 Electronic unit Figure 3 4 1 Switch board and power supply unit board Figure 3 4 2 Layout of components inside PSW 2G6F UPS Box...

Page 10: ...rs Pairs 1 2 and 3 6 Option A Pairs 4 5 and 7 8 Option B Item IEEE802 3at video camera Passive PoE TFortis TH camera housing IV IEEE802 3at video camera III IEEE802 3at video camera II I IMPORTANT If...

Page 11: ...15W 30W TFortis TH PoE 30W PoE B 15W PoE A 15W Passive PoE B 15W PoE B 30W PoE 30W Figure 3 4 3 PoE power supply scheme various options 3 4 2 START button To start the system supply from the battery p...

Page 12: ...2 and 3 6 The PoE B indicator is ON when power is supplied by free pairs pairs 4 5 and 7 8 3 4 8 LINK indicators Blinking of LINK indicators shows that data are transmitted via the corresponding port...

Page 13: ...Figure 3 5 2 Input supply voltage of 230 VAC comes to the terminals with a cross section of up to 2 5 mm2 The circuit breaker is designed to connect and disconnect the supply voltage of 230 VAC Note...

Page 14: ...14 Figure 3 5 3 230 VAC power supply terminal is disconnected Figure 3 5 4 Disable the battery to fully de energize the device...

Page 15: ...nected to SENSOR 2 contact The cabinet door opening will generate an alarm message to be sent to the server via SNMP Traps SMTP or Syslog protocols see detailed information in the Configuration Manual...

Page 16: ...7 1 with performance criteria B temporary disruption of performance or functioning with further recovery without operator s intervention Table 3 7 1 Port Pulse 2 kV 4 kV 2 kV IMPORTANT Grounding of th...

Page 17: ...nal from the IP camera If the switch fails to detect the Link signal then a one minute timer is started and after that the connection is checked again If the Link signal does not appear the switch rem...

Page 18: ...the fault The cable tester is used to test pairs that transmit data 1 2 and 3 6 Note that the accuracy of the cable tester is 2 meters By default VCT operates on an average algorithm and does not tak...

Page 19: ...ery power IMPORTANT Switching to battery power does not cause interruption in operation of the switch Deviations in the external power supply may be caused by phase imbalance loss of neutral 380 V soc...

Page 20: ...CC 1A With the increase in battery power battery voltage increases too As soon as it reaches 27V charging converts to direct voltage CV 27V In this mode voltage gets stable and current drops with the...

Page 21: ...V the battery goes off This allows to prevent deep discharging of the battery Table 3 9 3 1 BAT indicator State Description Battery disconnected or switch de energized Battery charging Battery dischar...

Page 22: ...values are recommended for use during system design When operated from the battery the switch estimates actual power consumption remaining battery capacity and calculates remaining battery time This i...

Page 23: ...rged battery until it is discharged to reach the final voltage Battery capacity changes throughout the service life During operation the capacity remains stable for a while and then begins to graduall...

Page 24: ...p to 100 m Main power supply voltage 230 VAC 187 to 253 V Maximum power consumption 320 W battery characteristics nominal voltage 12 V capacity 12 A h dimensions 151x98x95 mm quantity 2 Design dimensi...

Page 25: ...button until the DEFAULT indicator lights up The default IP address of the switch is 192 168 0 1 6 2 IP address setting All software functions of the switch can be managed configured and monitored usi...

Page 26: ...this data After the password is set you will need to authenticate when you log in Figure 6 3 Entering user name and password IMPORTANT Note that the user name and password are case sensitive 6 4 Setti...

Page 27: ...cameras press Manual Start 6 6 Activation of redundancy protocols If you connect the switches into a ring topology then you need to enable the RSTP protocol Otherwise if there are alternative paths yo...

Page 28: ...28 Figure 7 1 Battery compartment removal Figure 7 2 Electronic unit removal...

Page 29: ...re 7 3 The marking template is included with the packaging Figure 7 3 Marking of attachment points IMPORTANT Drilling of the enclosure will lead to loss of the switch integrity and result in the loss...

Page 30: ...ength member metal supports with screws are used Optical fibers are laid in a splice cassette for 32 shrinkable plastic sleeves Welded pigtails are connected to SC adapters located on the adapter pane...

Page 31: ...oving the battery compartment from the enclosure disconnect the power supply cables from the battery The battery shelf has holes for the bolts that fix the battery compartment To remove the compartmen...

Page 32: ...ctly 7 6 Power supply connection The switch is connected to 230VAC source Power supply cable is pulled into the unit through PG13 5 cable gland and is connected to the power supply unit section 3 5 Fi...

Page 33: ...king deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemicals or fluids severe contamination insects presence or signs of insects pres...

Reviews: