25
5 Operating conditions
The switch is designed for 24-hour operation in outdoor conditions at an
ambient temperature from
–60 to +50
C with industrial SFP modules.
It is recommended to install the switch in areas protected from direct sunlight
(under roof overhang, on shaded sides of the building, etc.).
The switch remains fully functional after exposure to ambient temperatures from
minus 60
C to plus 50
C.
6 Preliminary setting
It is recommended to do preliminary setting of the switch before installation. You
can find a detailed instruction in the "Configuration Manual" at TFortis website
(https://tfortis.com/support/dokumentaciya-na-produkciyu/).
6.1 Resetting the switch to factory settings
Before start, set the switch to default settings. To do this, press and hold the
DEFAULT button until the DEFAULT indicator lights up. The default IP address
of the switch is 192.168.0.1.
6.2 IP address setting
All software functions of the switch can be managed, configured and monitored
using the built-in WEB interface and Telnet. Below is the description of WEB-
based configuration. Configuration via Telnet (see the Configuration Manual).
The switch can be managed from remote stations at any point of the network
via a standard web browser (for example, Microsoft Internet Explorer). The
browser is a universal access tool and can directly access the switch using the
HTTP protocol.
Connect any switch port to an Ethernet network. Note that if the device is
configured over a network, the IP address of the management workstation
should belong to the same IP network. For example, if the default IP address of
the switch is 192.168.0.1, then the IP address of the workstation should be
192.168.0.x (where x is a number from 2 to 254); the default subnet mask is
255.255.255.0.