3.1 Ambient Temperature
Ambient temperature: 0
40
3.2. Relative humidity(RH):
Max. humidity: 95%
3.3. Medium (liquid delivery) temperature
Liquid delivery temperature: +2
℃
110
To avoid condensation in control box and the stator, the temperature of liquid
pumped by the motor pump must be always higher than ambient temperature.
3.4. System Pressure
Maximum pressure 1.0MPa(10bar).
3.5. Degree of Protection
IP 44
3.6. Inlet Pressure
.
℃
~+
℃
~
℃
Liquid Temperature
<85
℃
90
℃
110
℃
Inlet Pressure
0.05bar
0.28bar
1bar
0.5m head
2.8m head
3.7.
Pumping Liquid
The pumping liquid includes thin, clean, non-corrosive and non-explosive liquid
which shall not contain any solid particles, fiber or mineral oil, and the pump must
definitely not be used to pump inflammable liquid such as rapeseed oil and gasoline.
If the pump is used in a place with relatively high viscosity, the pump has lower
performance
.
So when choosing a pump, the viscosity of liquid must be taken into
account.
3. Operating Conditions
10m head
04
APUMP-HE