24
SETTING UP
1.
First, insert the batteries in the transmitter
(see “T
o
install and replace batteries in the thermo-hygro
transmitter
”
above).
2.
Within 2 minutes of powering up the transmitter,
insert the batteries in the
weather station (see “
To
install and replace batteries in the weather
station
”
above). Once the batteries are in place, all
segments of the LCD will light up briefly. Following
the indoor temperature/humidity and the time as
00:00 will be displayed. If these information are not
displayed on the LCD after 60 seconds, remove the
batteries and wait for at least 60 seconds before
reinserting them. Once the indoor data is displayed
user may proceed to the next step.
3.
After the batteries are inserted, the weather station
will start receiving data signal from the transmitter.
The outdoor temperature and humidity data should
then be displayed on the weather station. If this
does not happen after 2 minutes, the batteries will
need to be removed from both units and reset from
step 1.
4.
In order to ensure sufficient 868 MHz transmission
however, the distance between the weather station
and the transmitter should not be more than 100
meters (see notes on “
Positioning” and “868 MHz
Reception
”).
Note:
In the event of changing batteries of the units,
ensure the batteries do not spring free from the
contacts. Always wait at least 1 minute after
removing the batteries before reinserting, otherwise
start up and transmission problems may occur.
5.
Once the outdoor data reception test period is
completed, the DCF tower icon in the clock display
will start flashing in the upper left corner. This
indicates that the clock has detected that there is a
radio signal present and is trying to receive it. When
the time code is received, the DCF tower becomes
permanently lit and the time will be displayed.
Summary of Contents for Xeno 35.1111.IT
Page 130: ...129 LCD DCF ON OFF...
Page 131: ...130 12 8 MIN MAX RH 868 2 A IEC LR3 1 5 1 2 3 4...
Page 132: ...131 2 IEC LR6 1 5 1 2 3 30...
Page 133: ...132 1 2 2 0 00 60 60 3 2 1 4 868 100 868 1 DCF 1500...
Page 134: ...133 MIN MAX SET 1500 DCF 02 00 03 00 03 00 06 00 06 00 02 00 DCF DCF DCF DCF 1 5 2 3...
Page 135: ...134 SET ON OFF MIN MAX MAX MIN 5 RH DCF C C RH...
Page 136: ...135 SET 0 1 2 Key 0 12 12 0 c 1 3 SET DCF 1 2 Key...
Page 137: ...136 3 SET 4 Key 5 SET DCF 1 1 2011 1 2 Key 2011 2039 3 SET 4 Key 5 SET 6 Key 7 SET 135...
Page 138: ...136 DCF DCF 1 ON 2 Key 3 SET DCF 8 PM PM 137...
Page 139: ...138 12 24 75...
Page 140: ...RH C 30 12 24 139...
Page 141: ...140 MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX 3 MIN MAX 868 C RH...
Page 142: ...141 5 5 3 1 2 2 3 868 868 868 100...
Page 143: ...142 1 5 2 1 2...
Page 144: ...143 9 9 59 9 0 1 OF L 39 9 59 9 0 1 OF L 20 95 1 OL F 19 20 96 95 1 99 1 OF L 1 1 99 99...
Page 145: ...144 16 64 4 100 2 IEC LR6 1 5V 2 IEC LR3 1 5V 24 100 x 23 3 x 159mm 36 16 102 6mm...
Page 146: ...145 TFA Dostmann Wertheim 30 3187 IT EJIN9061T111 Printed in China...