SECTION 3
LYCOMING OPERATOR’S MANUAL
OPERATING INSTRUCTIONS
O-360 AND ASSOCIATED MODELS
(2) Set carburetor heat control in off position.
(3) Set propeller governor control in Full RPM position (where applicable).
(4) Turn fuel valves On.
(5) Move mixture control to Full Rich.
(6) Turn on boost pump.
(7) Open throttle approximately ¼ travel.
(8) Prime with 1 to 3 strokes of manual priming pump or activate electric primer for 1 or 2 seconds.
(9) Set magneto selector switch (consult airf
rame manufacturers handbook for correct position).
(10) Engage starter.
(11) When engine fires, move the magneto switch to Both.
(12) Check oil pressure gage. If minimum oil pressure is not indicated within thirty seconds, stop
engine and determine trouble.
b. Engines Equipped with Pressure Carburetors or Bendix Fuel Injectors.
(1) Perform pre-flight inspection.
(2) Set carburetor heat or alternate air control in
Off position.
(3) Set propeller governor control in Full RPM position (where applicable).
(4) Turn fuel valve On.
(5) Turn boost pump On.
(6) Open throttle wide open, move mixture control to
Full Rich until a slight but steady fuel flow is
noted (approximately 3 to 5 seconds) then return thro
ttle to Closed and return mixture control to
Idle Cut-Off.
(7) Turn boost pump Off.
(8) Open throttle ¼ of travel.
(9) Set magneto selector switch (consult airf
rame manufacturers handbook for correct position).
(10) Engage starter.
3-2