Description

The Greenlee CM-660, CM-860, CM-960, CMH-600, and CMI-600 Clamp Meters are 

hand-held testing devices with the following measurement capabilities:  AC and DC 

voltage, AC current, AC current AmpTip™, frequency, non-contact electric field (EF)

detection, and resistance. They also check diodes and verify continuity. These meters 

are designed to be placed on or removed from insulated or uninsulated conductors.

Additional functionality specific to each model includes:

Function

CMI-600

CM-960

CMH-600

CM-860

AC + DC Voltage

DC Current AmpTip™

DC + AC Current AmpTip™

DC Current

µDC Current

Temperature (K-style 

thermocouple)

Motor Rotation

Phase Rotation

Peak RMS Capture

Capacitance

Backlight

Zero Mode

Other capabilities include:

• Hold Mode to capture the present LCD value
• Record Minimum, Maximum, or Average Mode
• Intelligent Auto Power Off
• Automatic ranging

Safety

Safety is essential in the use and maintenance of Greenlee tools and equipment. This 

instruction manual and any markings on the tool provide information for avoiding 

hazards and unsafe practices related to the use of this tool. Observe all of the safety 

information provided.

Purpose of This Manual

This instruction manual is intended to familiarize all personnel with the safe operation 

and maintenance procedures for the Greenlee CM-660, CM-860, CM-960, CMH-600, 

and CMI-600 Clamp Meters.
Keep this manual available to all personnel. Replacement manuals are available upon 

request at no charge at www.greenlee.com.

Summary of Contents for Greenlee CM-660

Page 1: ...3 Greenlee Textron Inc 12 13 Clamp Meters INSTRUCTION MANUAL CM 660 CM 860 CM 960 CMH 600 CMI 600 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www Test...

Page 2: ...se Rotation Peak RMS Capture Capacitance Backlight Zero Mode Other capabilities include Hold Mode to capture the present LCD value Record Minimum Maximum or Average Mode Intelligent Auto Power Off Aut...

Page 3: ...r property damage Read and understand this material before operating or servicing this equipment Failure to understand how to safely operate this tool could result in an accident causing serious injur...

Page 4: ...ood condition Do not use the test lead if the contrasting inner layer of insulation is visible Use this unit for the manufacturer s intended purpose only as described in this manual Any other use can...

Page 5: ...accurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the measurement function while the test leads are connected to a componen...

Page 6: ...gative common or ground input terminal L1 input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or fingers below the dashed line during operation...

Page 7: ...cles per second 14 Ohm 15 k Kilo 103 16 AmpTip function is enabled 17 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with filter for accuracy on variable frequency drive...

Page 8: ...he actual value This modified value is shown on the LCD Note operation when DCA or DC ACA functions are selected offsets any mag netic hysteresis in the jaw If DCA or DC ACA reading before measuring i...

Page 9: ...th of the probe tip to 4 mm for measurement categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this...

Page 10: ...rue RMS provides much more measurement versatility The Greenlee CM 660 CM 860 CM 960 CMH 600 and CMI 600 are true RMS meters The Waveforms and Crest Factors table shows some typical AC signals and the...

Page 11: ...ncy noise on a 50 60 Hz power line Operation Electric shock hazard Contact with live circuits could result in severe injury or death Operating Procedure 1 Refer to the Settings Table Set the selector...

Page 12: ...00 Only Capacitance F COM CM 960 and CMI 600 Only Voltage AC DC COM Current AmpTip DC A N A N A Current AmpTip AC DC A N A N A Current DC A N A N A Current AC DC A N A N A CMH 600 and CMI 600 Only Tem...

Page 13: ...5 1 at full scale Crest factor 5 0 1 at half scale Frequency Function Sensitivity Sine RMS Range 600 V 50 V 5 00 Hz 999 9 Hz 60 0 A AmpTip 40 A 50 00 Hz 400 0 Hz 60 00 A 600 0 A 40 A 50 00 Hz 400 0 Hz...

Page 14: ...60 00 A 1 5 0 05 A For CM 660 CM 860 and CMH 600 only For CM 960 and CMI 600 only induced error for adjacent current carrying conductors is 0 01 A A AmpTip DC Current CM 960 and CMI 600 only Range Ac...

Page 15: ...fied 0 20 A to 5 99 A 1 8 0 15 A 2 0 0 15 A 6 00 A to 60 00 A 1 8 0 05 A 2 0 0 05 A 600 0 A 60 0 A to 600 0 A 1 8 0 5 A 2 0 0 5 A For any measurement when the conductor is not positioned on the center...

Page 16: ...VDC Continuity Tone Threshold Between 10 and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance CM 860 CM 960 CMH 600 and CMI 600 only Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2...

Page 17: ...e 2 000 V Accuracy 1 5 0 005 V Test Current typical 0 3 mA Open Circuit Voltage typical 3 5 VDC Temperature SELECT Temperature CMH 600 and CMI 600 Range Accuracy 40 0 C 99 9 C 1 0 0 8 C 100 C 400 C 1...

Page 18: ...e a dedicated switch position A Non contact OR B Contact precision measurement Non contact EF Detection Typical Voltage Range at 50 Hz to 60 Hz LCD Indication 20 V 10 V 36 V 55 V 23 V 83 V 110 V 59 V...

Page 19: ...e all models and DC A mode CMH 600 and CMI 600 Total Accuracy Specified Accuracy 25 digits In an RF field of 3 V m all other modes and models not specified above Total Accuracy Specified Accuracy 20 d...

Page 20: ...long branch circuits Measurement Category III Distribution level Permanently installed machines and the circuits they are hard wired to Some examples include conveyor systems and the main circuit bre...

Page 21: ...placing the Batteries 1 Disconnect the unit from the circuit Turn the unit OFF 2 Remove the two screws from the battery access door and remove it 3 Replace the batteries making sure to observe the pol...

Page 22: ...or their useful life excepting normal wear and abuse This warranty is subject to the same terms and conditions contained in Greenlee Textron Inc s standard one year limited warranty For items not cove...

Page 23: ......

Reviews: