Typical Measurements and Accuracy
(cont’d)
Reverse Bias
Forward Bias
SELECT
Diode Measurement
Diode Test
Measuring Range: 2.000 V
Accuracy: ± (1.5% + 0.005 V)
Test Current (typical): 0.3 mA
Open Circuit Voltage (typical):
< 3.5 VDC
Temperature
SELECT
Temperature (CMH-600 and CMI-600)
Range
Accuracy*
-40.0 °C ~ 99.9 °C
± (1.0% + 0.8 °C)
100 °C ~ 400 °C
± (1.0% + 1 °C)
-40.0 °F ~ 211.8 °F
± (1.0% + 1.5 °F)
212 °F ~ 752 °F
± (1.0% + 2 °F)
* K-type thermocouple accuracy not included.
Thermocouple supplied with meter meets
standard JIS C 1602-1981.