915FS Splicer
Greenlee / A Textron Company
1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
24
Heater Mode Menu (H–Mode)
There are 20 user-programmable heating modes. Select the one most suitable for the
protection sleeve used.
Each tube-heating mode is optimized for a type of protection sleeve. These modes can
be found in the database area for reference. Copy the appropriate one and paste it into
the user-programmable area. The operator can edit the user-programmable modes.
(1) Select Heater Mode
Select “H–Mode” to access the available heater modes. Use
p
and
q
to highlight the
desired heater mode. Then press
8
to confirm.
Select the heater mode most suitable for the protection sleeve to be used.
Press
p
or
q
to select a heater mode. Then press
8
to confirm.
(2) Edit Heater Mode
Tube-heating conditions stored in heater mode can be edited or changed.
Editable parameters include Heat Time and Heat Temp (heating temperature). Heat
Time will automatically adjust according to atmospheric conditions, e.g., ambient
temperature. The real Heat Time may vary from set Heat Time.
Sets Heating Temperature: Fiber coating may melt if Heat Temp is over 190 °C (374 °F).
Sets Finish Temp (Finish Temperature): When heater approaches this temperature, the
buzzer beeps, announcing the sleeve is cooled down and is ready to be removed from
the heater.