CLEAN-UP VACUUMING

Do not vacuum or blow burning or 

toxic materials such as carcinogens, 

asbestos, pesticides or heavy metals.

Wear eye protection and a dust mask 

when operating or servicing this tool. 
Failure to wear eye protection could 

result in serious eye injury from flying 

debris.

Use extra care when cleaning on stairs.
Failure to observe this warning could result in severe 

injury or death.

•  Do not use without a clean filter in place. Using 

the vacuum/blower with a clogged, damaged or 

missing filter will cause damage to the motor.

•  Do not vacuum up anything that is burning or 

smoking, such as cigarettes, matches or hot ashes.

Failure to observe these warnings may result in 

severe injury or death.

Wet Pickup

This unit is equipped with a shut-off float valve. When 

the unit is used for wet pickup, the rising fluid lifts 

the float valve until it seals against the motor intake. 

When this happens, the sound of the motor changes 

to a higher pitch. Unplug the unit, empty the tank, and 

replace the cover.

Dry Pickup

For optional dry pickup accessories, refer to the 

“Optional Equipment” at the end of the “Parts 

List—690.”

Maintenance

Electric shock hazard:
Disconnect from power before 

servicing.
Failure to observe this warning could 

result in severe injury or death.

Note:  Keep filters clean. Efficiency of this vacuum is 

largely dependent on the cleanliness of the filters. A 

clogged filter can cause overheating and damage to the 

motor. Filters should be removed and cleaned periodi-

cally to ensure proper operation. After cleaning, allow 

filters to dry thoroughly to prevent deterioration.

Filters and Gaskets

1.  Unplug the unit.
2.  Remove the tank cover (21).
3.  Carefully remove the filters (28, 28A) from the filter 

basket (25). Refer to the illustration.

25

28

28A

4.  Clean the filters with a mild detergent and warm 

water. Allow them to dry thoroughly.

5.  Inspect the gaskets (22, 23). Replace if necessary.
6.  Install the filters. Install the tank cover and secure 

with the catches.

Summary of Contents for Greenlee 690

Page 1: ...2010 Greenlee Textron Inc IM 1283 REV 6 12 10 Includes Serial Number AAR 3800 and higher Read and understand all of the instructions and safety information in this manual before operating or servicing...

Page 2: ...enlee com Do not discard this product or throw away For recycling information go to www greenlee com All specifications are nominal and may change as design improvements occur Greenlee Textron Inc sha...

Page 3: ...se attention is necessary when used by or near children Use only as described in this manual Use only manufacturer s recommended attachments Do not put any object into openings Do not use with any ope...

Page 4: ...arettes matches or hot ashes Failure to observe these warnings may result in severe injury or death Note Keep all decals clean and legible and replace when necessary Grounding Instructions Electric sh...

Page 5: ...for vacuuming Exhaust Port for blowing Specifications Motor 12 amps 120 VAC 60 Hz Pressure Blower 0 275 bar 4 psi Vacuum Column of Water 2 8 m 110 Column of Mercury 203 mm 8 Air Flow 3 4 m3 min 120 ft...

Page 6: ...uit at high speed Attach the warning tag at the exit end of the conduit before blowing a piston through the conduit Failure to wear eye protection could result in serious eye injury from flying debris...

Page 7: ...8 USA 815 397 7070 7 Operation cont d VACUUMING BLOWING WITH OPTIONAL 592 MIGHTY MOUSER BLOWING Cone 1 1 4 to 2 1 2 Cone 3 to 4 Cone 1 2 to 1 Washer 5 and 6 optional Adapters CAUTION 1 3 2 Line Tied t...

Page 8: ...uid lifts the float valve until it seals against the motor intake When this happens the sound of the motor changes to a higher pitch Unplug the unit empty the tank and replace the cover Dry Pickup For...

Page 9: ...does not develop adequate vacuuming or blowing pressure Filters are dirty Clean the filters Refer to the Maintenance section of this manual Gaskets do not seal well Replace gaskets Refer to the Mainte...

Page 10: ...ing Dr Rockford IL 61109 2988 USA 815 397 7070 10 Illustration 690 27 20 10 22 21 51 50 19 17 14 12 13 16 15 43 49 11 47 26 18 23 24 28 28A 25 1 5 7 6 42 3 4 46 2 44 46 45 8 CAUTION 41 40 38 37 36 35...

Page 11: ...Screw pan head 8 18 x 3 8 4 18 Nut Nylock hex 1 4 20 3 19 Screw round head machine 8 32 x 1 2 1 20 50022628 Rainhat and decals 1 50321188 Tank cover motor mount includes items 9 21 28A 1 21 50313568...

Page 12: ...MT 1 646 Piston for 3 1 2 EMT 1 622 Piston for 3 EMT 1 623 Piston for 4 EMT 1 42 50340271 Storage box for accessories 1 43 91867983 Strain relief 1 44 90533712 Catch 3 45 Screw fillister head machine...

Page 13: ...inger 2 116 Clamp 2 117 91861268 Brush mechanism 2 118 Bracket 1 Serial No AAR Key 10 mm Armature Description Qty Serial No AAR Key 10 mm Armature Description Qty 119 Spacer 1 120 Fan ventilating 1 12...

Page 14: ...524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc www greenlee...

Reviews: