690 Power Fishing System
Greenlee / A Textron Company
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
6
Setup
1. Unfasten the catches. Remove the motor cover and
remove the hose from the tank. Install the cover and
latch the catches.
2. Attach the storage box to the tank by position-
ing the box over the triangular rib on the tank and
sliding the box down firmly until it locks into place.
Operation
• Wear eye protection and a dust
mask when operating or servicing
this tool.
• Piston and debris will exit the
conduit at high speed. Attach the
warning tag at the exit end of the
conduit before blowing a piston
through the conduit.
Failure to wear eye protection could
result in serious eye injury from flying
debris.
Use the 690 alone, or combine it with a 592 Mighty
Mouser
®
as shown here.
OPERATING TIPS
• When fishing through IMC or rigid, blowing is
generally more efficient than vacuuming.
• When fishing through EMT, vacuuming is the better
method. EMT connections are not airtight, and a
piston that is blown through might not reach the exit
end of the conduit run.
• Two fishing lines can be vacuumed in at the same
time, if desired. Leave one line in the conduit to
pull additional wire into the conduit after the initial
installation.