background image

2

INS161

1.

 

INSTALLATION

The 

Premier RKP4, RKP8 

and

 RKP16

 Remote Keypads are suitable for use

with the following Texecom Control Panels: 

Premier 400

Premier 412

,

Premier 800

 and 

Premier 816.

 Up to 6 keypads may be connected to the

system.

1.1

 

Mounting

Open the keypad by carefully inserting a small flat-blade screwdriver into
either half of the double slot at the base of the unit. Gently twist the
screwdriver to ease the retaining clips. Do NOT use excessive force. The
front and flap can now be removed.

The PCB assembly is hinged for easy access. Alternatively the PCB
assembly can be unclipped and completely removed if required.

Mount the keypad using at least two appropriate countersunk screws (no
larger than No. 6). A keyhole slot has been provided to assist mounting and
aid levelling.

1.2

 

Selecting an Address

Each keypad MUST be given a different address using the DIP switch on the
side of the PCB as follows:

Address

DIP 1

DIP 2

DIP 3

DIP 4

1

Off or On

Off

Off

Off

2

Off

On

Off

Off

3

Off

Off

On

Off

4

Off

Off

Off

On

5

On

Off

Off

On

6

Off

On

Off

On

NEVER set two RKPs to the same address.

Keypads are factory set to address 1 (all switches off).

1.3

 

Wiring

It is strongly recommended that the system is completely powered down
(mains and battery) before wiring a keypad. Connect the keypad to the
control panel using 4-core cable as follows:

!

Reviews: