5. How to identify the LED status of sensor?

Ans: 

Below are the detailed details of the LED status.

Colour Status

Description

Flashing 

Green

Comfort LED. When the reed switch is closed, the comfort 

LED will flash green approximately every 3sec to indicate 

correct operations.

Momentary 

Green

Background disturbance/under-sensitive setting. This is 

used to indicate background disturbances or an under-

sensitive setting during installation.

Momentary 

Red

Alarm condition/correct sensitivity. This is used to indicate 

that an attack has been detected by the shock sensor or 

a correct sensitivity setting during installation.

Momentary 

Orange

Gross attack /over-sensitive condition. This is used to 

indicate that a massive attack has been detected by the 

shock sensor or an oversensitive setting during installation.