Technical Support
:
91520 10269
:
Press Menu ( ) two times
on the control panel and then press
Yes
to logoff
from your control panel
Frequently Asked Questions:
1. How to enable reed?
Ans:
Inside the device we have an option for reed enable & disable. Below
image will give you an idea for place magnetic contact distance.
Press Yes
7times to reach zone mode(wiring) & make zone wiring as
“always awake”
3. How to adjust the range?
Ans:
Inside the device we have an option for adjusting the range of sensor with
2 pins inside & below image is for your reference.
2. What would be the maximum distance between the device and magnetic
contact?
Ans:
The magnetic contact distance is
Non-Ferrous
Mounting Material
Ferrous Mounting
Material
Maximum Break
30mm
15mm
Minimum Make
15mm
5mm
4. How to adjust the sensitivity of the vibration in this device?
Ans:
Inside the device we have an option for adjusting the sensitivity. If we
adjust the sensitivity in clockwise direction, it will increase the sensitivity & in anti-
clockwise direction, it will decrease the sensitivity of the sensor.