Texecom Premier Elite Impaq Plus-W Quick Start Manual Download Page 2

Technical Support

91520 10269                                                          

[email protected]

Press Menu (      ) two times 

on the control panel and then press 

Yes

to logoff 

from your control panel

Frequently Asked Questions:

1. How to enable reed?

Ans: 

Inside the device we have an option for reed enable & disable. Below 

image will give you an idea for place magnetic contact distance.

Press Yes         

7times to reach zone mode(wiring) & make zone wiring as 

“always awake”

3. How to adjust the range?

Ans: 

Inside the device we have an option for adjusting the range of sensor with 

2 pins inside & below image is for your reference.

2. What would be the maximum distance between the device and magnetic 

contact?

Ans: 

The magnetic contact distance is

Non-Ferrous 

Mounting Material

Ferrous Mounting 

Material

Maximum Break

30mm

15mm

Minimum Make

15mm

5mm

4. How to adjust the sensitivity of the vibration in this device?

Ans: 

Inside the device we have an option for adjusting the sensitivity. If we 

adjust the sensitivity in clockwise direction, it will increase the sensitivity & in anti-

clockwise direction, it will decrease the sensitivity of the sensor.

Reviews: