1. Regulatory Requirements 

 General 

The 

Premier ComISDN

 digimodem must be installed by an electrically competent 

person. Before attempting to install the digimodem, the installer must be aware of 
the regulatory requirements detailed in this section. 

The digimodem is suitable for connection to the following types of telephone line: 

• 

Integrated Services Digital Network (ISDN) 

Approval 

The 

Premier ComISDN 

digimodem is manufactured to meet all European Area 

telecommunication network requirements. These devices have been approved for 
use with Council Decision 97/346/EEC for pan-European single terminal connection 
to the Integrated Services Digital Networks (ISDN). However due to differences 
between the individual ISDNs provided in different countries, the approval does not 
in itself give unconditional assurance of successful operation with every ISDN 
network termination point. 

In the event of problems, you should contact Technical Support at Texecom Ltd. 

The 

Premier ComISDN

 digimodem has been approved for the following usage: 

• 

Automatic Call Initialisation 

• 

Automatic Dialling  

• 

Modem 

• 

Multiple Repeat Attempts 

• 

Line Status Monitoring 

Any other usage will invalidate any approval given to the devices and as a result the 
devices will cease to comply with the standards against which the approval was 
granted. 

 

Summary of Contents for Premier ComISDN

Page 1: ...INSTALLATION MANUAL Digi modem Issue 3 THANK YOU FOR VOTING TEXECOM...

Page 2: ...Operation 6 Communicator Operation 6 Modem Operation 6 3 Installation 7 Plugging on the Digimodem 7 ISDN Line Connections 8 Setting up the Com Ports 8 Programming the ComISDN 9 Testing 9 Testing the...

Page 3: ...ved for use with Council Decision 97 346 EEC for pan European single terminal connection to the Integrated Services Digital Networks ISDN However due to differences between the individual ISDNs provid...

Page 4: ...tal communicator supporting Fast Format Contact ID SIA Level II and EasyCom Pager protocols 6 Alarm Receiving Centre telephone numbers up to 24 digits each Fully programmable reporting codes Contact I...

Page 5: ...S187 5 ComISDN Layout Connection Plug RJ45 Connector ISDN Com 1 RJ45 Socket ISDN Direct connection for ISDN telephone line see page 8 for wiring details Connection Plug Plugs into digimodem socket on...

Page 6: ...m will send a handshake signal If the handshake signal is acknowledged the digimodem will report the event to the Alarm Receiving Centre using Fast Format Contact ID or SIA Level II If the handshake s...

Page 7: ...ase of the control panel the two short pillars are fitted closest to the control panel 4 Ensure that the board is the correct way up see picture below 5 Locate the 8 pin plug on the digimodem into the...

Page 8: ...end into the ComISDN and feed the other end through the cable entry 4 Plug the other end of the RJ45 cable into a suitable ISDN terminal ComISDN ISDN Terminal RJ45 Lead Setting up the Com Ports To set...

Page 9: ...nels For Fast format select the Open Close channels For all other formats select the Areas that will report events For all other formats select the types of events that will be Reported Select any Con...

Page 10: ...LED returns to its normal mode 6 Finally replace and secure the control panel cover Using a PC for local Upload download When connecting a PC to the control panel proceed as follows 1 Unplug the ComI...

Page 11: ...Protocol V 21 300 baud Analogue to Digital V 120 19200 baud Digital to Digital Telephone Numbers 6 up to 24 digits each Dialling Formats DTMF Digital Approval CTR3 A1 Environmental Operating Temperat...

Page 12: ...testing As a result the Premier ComISDN digimodem are covered by a two year warranty against defects in material or workmanship As the Premier ComISDN digimodem is not a complete alarm system but onl...

Reviews: